Configuring the system software
7.7
Fixing the cover frame
A
NOTICE! Damage hazard
Tighten the screws carefully in order not to damage the cover frame.
➤ Fix the cover frame in place as illustrated (fig. c).
The distance "x" has to be measured again. This measure is needed to determine
the spacer and screw length for the fastening of the cover frame.
Example:
• Screw length = x + (23 to 27) mm:
In case "x" is 51 mm, the suitable screw length is 75 mm
• Spacer length = x + 9 mm:
In case "x" is 51 mm, the suitable spacer length is 60 mm
8
Configuring the system software
Before the system is first put into operation, the control unit settings can be
adjusted to suit the various installation conditions. Those adjustments must be
made by the installer (fig. 5).
Display
indication
P.01
P.02
I
NOTE
Configuration mode can still be activated if the low voltage cut-out has
switched off the system and only residual voltage is available.
12
Parameter
Meaning
Low voltage
The battery monitor shuts down the
shut-down
system at the voltage defined here.
RTX 24 V
RTX 12 V
Unit for tempera-
The temperature can be displayed in
ture display
°C or °F.
CoolAir
Factory
setting
22.8 V
11.5 V
°C
EN