Installation
➤ Screw the 4 self-tapping M6 threaded plugs into the blind holes marked "7".
Use a 5 mm hexagon bit to do so.
➤ Screw the 4 self-tapping M8 threaded plugs into the blind holes marked "6".
To do so, use the 1/4" bit supplied.
7.4

Attaching the seal for the cab roof

A
NOTICE! Damage hazard
Ensure that the surface where the seal between the unit and the cab roof is to
be glued is clean (free of dust, oil, etc.).
➤ Glue the sealing strip to the cab roof (fig. 9 A).
Follow the contour of the roof hatch opening. The join between the ends of
the seal should be at the back.
➤ Apply a flexible, non-hardening butyl sealant (e.g. SikaLastomer-710) to the
join between the ends of the sealing strip and to the top edge of the sealing
strip (fig. 9 B).
7.5

Fitting the unit in the roof hatch

!
CAUTION! Risk of injury
Only install the unit in support of e. g. second person, crane, working platform.
The work safety must be guaranteed at all times.
➤ Place the parking cooler as shown and facing forwards in the roof hatch
opening (fig. 0).
I
NOTE
Once the unit is in position on the vehicle roof, the seal should make contact all
the way round. Only then can a reliable seal be achieved.
➤ Position the fixing brackets underneath the cab roof (fig. a).
When doing so, slide the fixing brackets between the cab roof (chassis) and
the roof lining (if existing).
A
NOTICE! Damage hazard
Do not exceed the specified tightening torque under any circumstances. That
is the only way to ensure that the threaded plugs are not pulled out.
➤ Fix the parking cooler in place as illustrated (fig. a).