Mark out and fasten screws so that they protrude a few millimetres from both cupboard sides (figure 10, pos. A). If it
is intended to align the underside of the cooker hood with the underside of the row of cupboards, use the upper
measurement 102; see figure 10, pos. A. The cooker hood brackets are adjustable to fit various cupboard depths (fig-
ure 10, pos. B).
2. Move the cooker hood brackets without fully tightening the screws and adjust the brackets so that they fit the sides
of the cupboards (figure 10, pos. C). Hang the cooker hood in the pre-installed screws in the side of the cupboard.
Tighten the screws in the bracket and on the wall (figure 10, pos. D). Lock the brackets into position using the locking
screws (figure 10, pos. E).

6.3.2.3 Optional installation in a cupboard with a base

1.
Using a saw, cut out a hole in the base of the cupboard. When the SAVE VTR 150/B unit is mounted directly on the
wall, the minimum distance from the wall to the hole has to be 55 mm (figure 11, pos. A).
Note:
Be sure to add the thickness (dimension X) of your wooden blocks if they were used (figure 11, pos. B).
Fig. 10 Installation using brackets
Fig. 11 Dimensions of a hole in the base of the cupboard
GB