Herunterladen Diese Seite drucken

SystemAir SAVE VTR 150/B R 500W Betriebs- Und Wartungsanleitung Seite 20

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

16
| Installation
6.2.3.1 Wiring and configuration
Connect and configure control signal from the cooker
hood to the unit.
Installation and connection
1. Connect control signal wires from the cooker hood to
any free universal input and 24 V on the external con-
nection board (figure 3). For more information about
connection board see 8.2 External connections (Con-
nection board), page 48.
Note:
Configuration of the Cooker Hood Function
can be done only after the first power up of
the SAVE VTR 150/B unit and competed
startup wizard.
Configuration
1. Go to Service menu
2. Enter password (default 1111)
3. Go to Input menu. Select UNIVERSAL tab.
4. Select the universal input to which the cooker hood is connected. Example if it is connected to UI1 on the connection
board, then select UNIVERSAL INPUT 1. Set signal type as Digital input and select an option Cooker Hood
Function from the input type list.
Important
Make sure configuration is logged in the commissioning record!
6.3
Installation with 392–10/B cooker hood
The SAVE VTR 150/B is to be mounted above a stove.
Continue to follow instructions how to find the correct height and depth for mounting bracket installation.
Fig. 7 SAVE VTR 150/B in a kitchen environment
Fig. 3 Connection of the cooker hood
GB
212024 | A003, rev 29

Werbung

loading

Diese Anleitung auch für:

Save vtr 150/b