Important!
• The unit requires regular maintenance and therefore kitchen furniture panel between cabinets where the unit is lo-
cated must be removable.
• Depending on the cupboard depth and selected kitchen furniture panel installation method, the SAVE VTR 150/B unit
may have to me shifted forward using wood blocks at the back.
• Solutions how to hang this panel are described further in this document, see 6.4 Installation of a kitchen furniture
panel, page 22.
Make sure to find a correct depth for installation of the SAVE VTR 150/B unit before proceeding with the mounting
bracket installation on the wall.
The SAVE VTR 150/B is supplied with approximately 1,9 m of power cable and fitted with a plug for 230 V~, single
phase earthed connection located at the top of the unit.
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic etc. Stale discharge air should ideally be led via a roof unit to
the outside and with a good distance to any outdoor air intake, windows etc.
6.3.1
Wall preparation for mounting bracket
Important
Make sure to read all instructions before proceeding with installation procedure. Installation steps can vary
depending on the type of installation.
1. Prepare the surface where the unit is to be mounted. Make sure that the surface is flat, vertical and that it supports
the weight of the unit. Perform the installation in accordance with local rules and regulations.
212024 | A003, rev 29
Minimum distance between cabinets (mm)
SAVE VTR 150/B unit width (mm)
Minimum distance between stove surface and cooker
hood (mm)
Minimum distance between stove surface and cooker
hood (mm)
Distance between the unit and the cooker hood when
it is inserted directly into the unit (mm)
Note:
When flexible duct is used, distance between
the unit and cooker hood is decided by the
installer (minimum 100 mm).
The cooker hood height (mm):
Total height of the unit with inserted cooker hood
(mm):
Distance to the mounting bracket from the underside
of the cooker hood or underside of the cupboard if it is
aligned with the cooker hood (mm)
Note:
This distance must be increased according to
the increased measurement D if flexible duct is
used.
Installation |
600
596
450 (Recommended 500)
650
10
97
737
697
17