INTEGRAL POWER II
Control Panel
4
1.- On/off: unit on - off and mode selection F4 / F0 / F1 / F6
2.- Temperature selector (15-27° C – 59-80° F), Programming remote control,
degrees Fahrenheit and air speed: Ambience control temperature and centrifugal
blower speed (between 1st and 5th speed) manual mode only.
3.- Display: Screen indicating the selected function and the status of the unit.
4.- LED: On - indicates unit running F4 , F0 .
• When connecting, the unit checks the LEDs and displays:
- 88
-- IP 24 (in 24V units)
- 88
-- IP 12 (in 12V units)
and goes off.
Special display messages (please check Failure Troubleshooting):
lb : " Low battery" (the unit will beep for a few moments and the unit will turn off).
EO :
Poor contact of wires on return air sensor or return air sensor faulty.
E6 :
Poor contact of wires or anti-frost sensor faulty.
E2 :
Electrofan or blower failure.
E9 :
Compressor protection due to unit slant above 45º.
Turning the unit on
Press the On/Off key
in Function F4 (Automatic Function)
Keep the On/Off key
be displayed; release the key for the required function.
ºC
3
ºF
TEMP
to turn on the Integral Power II unit. The unit always starts up
pressed down to change function. The different functions will
+
2
-