Page 19 of 30 of European Technical Assessment ETA-22/0275, issued on 2022-11-07
Table B9.1
Conditions for proper installation and additional advice for installation
Note: Driving rain resistance must be designed in accordance with the provisions given in annex B2
for fasteners with an interior part made of galvanized steel.
≤8 mm
rendering
thickness
ETICS
rendered
with
plaster
>8 mm
rendering
thickness
* External Thermal Insulations Composite Systems (ETICS) or rendered insulation with reinforced plaster which are glued
only or glued and mechanically fixed.
** ≥ 5 kPa is a guideline value that the thermal separation module can apply sufficient pre-tensioning force in the insulation
panel to ensure the compression of the sealing ring.
The values stated are to be understood as guideline values in order to give the user the highest possible application safety
HIK-T 12, HIK-T 16
Intended use
Conditions for proper installation and additional advice for installation
HIK-T 12, HIK-T 16
ETICS* with insulation panels made of
XPS
Mineral wool,
EPS
compression
strength ≥ 5 kPa**
Standard installation in accordance with annex B5, B6,
B7 and B8
Drill the hole through the insulation and in the base
material with a regular drill bit. Afterwards, enlarge
the hole in the plaster to d=26 mm by using e.g., a
wood drill bit.
wood fiber, raw
wood fiber, raw
density
density >230kg/m
≤230kg/m
3
and
or compression
compression
strength
≤ 100 kPa
Drill the hole
through the
insulation and in the
base material with a
regular drill bit.
Afterwards, enlarge
the hole in the
plaster and
insulation to
diameter 26 mm to a
depth of 60 mm. For
this purpose a wood
drill bit may be
used.
Annex B9
3
strength
> 100 kPa