5.1 GROUPS OF DAYS

This function is used to set one of the 3 available weekly intervals, each with three hourly time bands for switching the boiler on
and off. These are preset but can be modified by the user - programme rows 501...506. The intervals are:
Mon - Sun (factory setting) / Mon - Fri / Sat - Sun.
If the system is divided into zones, each with its own Control Panel/Ambient Unit, each single zone must be individually set
on each device.

5.2 SINGLE DAYS

The daily boiler switching on and off phases can all be modified by the user. The 3 pre-set time bands are available for each single
selected day, as indicated in the table at the end of this section.

5.3 HOURLY PROGRAMMING EDIT PROCEDURE (heating / DHW)

After performing hourly programming using the preset programmes, it is always possible to modify the three time bands -
programme rows 501...506 for heating and 561...566 for DHW as described below.
HEATING CIRCUIT PROGRAMMING EDIT PROCEDURE
C
B
"Time central heating CH1"
B and the groups of days field (section GROUPS OF DAYS) starts flashing
B to confirm.
or "Single days")
B
programme row 514 (Select default timings?)
the "Groups of days" hourly programming (section GROUPS OF DAYS) or
programming: programme rows 501....506.
DHW CIRCUIT PROGRAMMING EDIT PROCEDURE
The procedure for enabling hourly programming of the DHW is the same as the hourly programming for the heating circuit. The
only difference is the name of the menu "Time hot water" and the programme rows to set 560 (Select days). To disable this
function, follow the procedure described in the "Resetting the Original Factory Programme" section.
SUMMARY TABLE
GROUPS OF DAYS
Weekly interval
Mon-Sun
Mon-Fri
Sat-Sun
SINGLE DAYS
Daily interval
Mon-Tue-Wed-Thu-Fri-
Sat-Sun
To simplify programming existing programmes can be copied to other days of the week. The following procedure is used.
COPYING A PROGRAMME TO ANOTHER DAY
After programming the time band of a certain day, it can be copied to one or more days of the week.
The parameter between brackets "( )" refers to hourly programming in DHW
• From programme row 514 (574) (if one of the 3 preset time bands has been used) or from programme row 501 (561) (if manual
programming has been performed) turn the knob clockwise to programme row 515 (575).
• Copy? appears on the display.
B
Copy to and the day of the week flashes.
B to scroll the days of the week, select which to copy the programme to and
• Repeat the above point to copy the same daily programme to other days.
C to return to the previous menu.
7219836.01 (1-04/15)
B
PROGRAMME ROW 514 (heating) / 574 (DHW)
On1 – Off1
06:00 – 08:00
06:00 – 08:00
PROGRAMME ROWS 501 502 503 504 505 506 (heating) / 561 562 563 564 565 566 (DHW)
On1 – Off1
06:00 – 08:00
programme row 500 (Select days).
B to scroll the days ("Groups of days"
B and
B to select one of the 3 pre-set programmes of
B clockwise by a click to pass to manual
Preset programmes
On2 – Off2
11:00 – 13:00
06:00 – 23:00
Preset programmes
On2 – Off2
11:00 – 13:00
B to confirm.
38
On3 – Off3
17:00 – 23:00
17:00 – 23:00
On3 – Off3
17:00 – 23:00