The spray gun must not be used for spraying
flammable substances. Do not clean spray guns
with flammable solvents.
WARNING!
Pay attention to the dangers that can be
caused by the sprayed substance and also
observe the labels on the containers or the
instructions given by the manufacturer of the
substance.
Original accessories/auxiliary
equipment
Only use the accessories and additional equip-
ment that are specified in the operating instruc-
tions and are compatible with the appliance.
WARNING!
Do not use any accessories that are not
recommended by PARKSIDE. This can lead to
electric shock and fire.
Safety guidelines for battery
chargers
This appliance may be used by
children aged 8 years and above
and by persons with limited phys-
ical, sensory or mental capabili-
ties or lack of experience and
knowledge, provided that they
are under supervision or have
been told how to use the appli-
ance safely and are aware of
the potential risks. Do not allow
children to use the appliance as
a plaything. Cleaning and user
maintenance tasks may not be
carried out by children unless
they are supervised.
GB │ IE
6 
To avoid potential risks, damaged
mains cables should be replaced
by the manufacturer, their cus-
tomer service department or a
similarly qualified person.
The charger is suitable
for indoor use only.
ATTENTION!
This charger can only charge the following
batteries: PAP 20 A1/PAP 20 A2/
PAP 20 A3/PAP 20 B1/PAP 20 B3/
PAPS 204 A1/PAPS 208 A1.
A current list of battery compatibility can
be found at www.Lidl.de/Akku.
Working procedures
Viscosity
This appliance can process spray materials up to
max. 70 DIN/sec (viscosity). You can determine
the viscosity (thickness) of the substance with the
supplied measuring cup
measuring procedure.
Fill the supplied measuring cup
with the spray material.
Remove the measuring cup
material and allow the liquid to run out.
Measure the time (in seconds) until the stream
of liquid stops. This time is called "DIN seconds
(DIN/sec)".
If the value is too high, gradually thin the spray
material by adding small amounts of a suitable
thinning agent and mixing the liquid.
Measure the DIN seconds again. Repeat the
process until you measure a viscosity of less
than 70 DIN/sec.
NOTE
Do not exceed the maximal viscosity of the
appliance. The spray material must not be too
thick. Otherwise, the appliance might clog.
using a simplified
to the brim
from the spray
PFSA 20-Li C3