2.4.
TRANSPORT
DANGER - WARNING
TO ENSURE SAFE TRANSPORT OF THE MACHINE FROM ONE WORK PLACE TO
ANOTHER, REPLACE IT IN ITS ORIGINAL PACKAGING.
2.5.
POSITIONING/WORK STATION
a. Position the machine on a work bench or on a pedestal at a height of between 900 – 950
mm from the ground. The surface on which the machine is placed must be big enough to
guarantee machine stability (Fig. 3A).
DANGER-WARNING MANUAL BANDSAWS
Machine positioning in the work area must be performed ensuring a clearance of
at least 800 mm on all sides of the machine (see Fig. 3B).
DANGER-WARNING AUTONOMOUS CUTTING BANDSAW
This model of machine must only be used in a dedicated environment/area to which
unauthorized access is prohibited.
If no such work area is available, it is advisable to cordon off the machine's operating
area (2 metres of clearance on all sides of the bandsaw) (Fig. 3B) using red and
white safety chains and yellow lines on the fl oor.
Put up a "No access to unauthorized persons" sign.
b. Position the machine in a work area with adequate lighting.
c. It is advisable to secure the machine to the workbench with M8 screws using the holes
provided on the base.
2.6.
ELECTRICAL CONNECTION
Safety Standards for electrical connections
-
Check that the mains system to which the machine is to be connected is earthed in
accordance with the relative safety regulations in force.
DANGER - WARNING
CHECK THAT THE POWER SUPPLY SYSTEM IS EQUIPPED WITH A THERMOMAGNETIC
CIRCUIT BREAKER TO PROTECT ALL CONDUCTORS FROM SHORT CIRCUIT AND
OVERLOADS (SEE APPENDIX).
Preliminary tests and checks after connection
DANGER - WARNING
- BEFORE CONNECTING THE MACHINE TO THE MAINS, CHECK THAT THE SUPPLY
VOLTAGE MATCHES THE VOLTAGE INDICATED ON THE MACHINE ITSELF.
- ONCE CONNECTED, TO AVOID ANY POSSIBLE RESIDUAL RISKS OF TRIPPING
AND FALLING, MAKE SURE THAT THE POWER SUPPLY CABLE LIES
COMPLETELY ON THE GROUND AND IS NOT AT ANY POINT RAISED IN THE
AIR.
28
ART. 780XL, 782XL, 783XL, SN105XL