Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LED
Nome
20a
Pre-gas
(Time in which the gas is made to flow
before the start of the welding process)
20b
Is
(current at the time the torch button is
20c
Up
(time in which the current passes
Frequency and pulsation duty-cycle
20d
Freq
(frequency in which the pulses are
20e
Duty
20f
I Back
20g
l2
20h
Sd
(time in which the current passes
20i
If
20l
Post-Gas
(Time in which the gas flows after the end of
the welding so that the torch can cool down)
Figure 8

RESET PROCEDURE

1) Press the "mode" button
2) Apply voltage to the system
Description
Pre-Gas Time
Initial Current
pressed and background ground)
Slope-UP Time
from the Is value to the I2 value)
repeated)
Pulsation duty – cycle
Background current
Welding current
Slope-Down Time
from the I2 value to the If value)
Final current
(final welding current)
Post-Gas time
Variation
Figure
range
T1 Fig 6
0 -20 s
da 5A al
Is Fig 6
valore I2
T2 Fig 6
0 -20 s
-
3 – 250Hz
-
12% - 90%
-
5 a 70 A
I2 Fig 6
-
If Fig 6
0 -2 0s
da 5A al
If Fig 6
valore I2
T4 Fig 6
0 – 20 s
Default
value
0,5 s
20 A
0,2 s
30Hz
50%
5
-
2s
20 A
5 s
15

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Tt 168hfTt 205hfTt 168dgtTt 205dgt

Inhaltsverzeichnis