Verfügbare Sprachen

Technical data
T
a
T
p
 24
Derating curve: 150 °C (302 °F)
1
I
: 200 mA (DC-PNP), 250 mA (AC/DC)
max
2
I
: 150 mA (DC-PNP), 150 mA (AC/DC)
max
Ta
Ambient temperature
Tp
Process temperature
12.3
Process
NOTICE
Pay attention to the pressure and temperature derating depending on the selected process
connection .
Process temperature range
Process pressure range
Density
State of aggregation
Viscosity
Solids contents
Lateral loading capacity
68
T
a
[°F]
[°C]
+158
+70
+50
+122
+32
0
–40
–40
–20
–4
–40 to +100 °C (–40 to +212 °F)
–40 to +150 °C (–40 to +302 °F)
Max. –1 to +40 bar (–14.5 to +580 psi)
> 0.7 g/cm³ (optionally available: > 0.5 g/cm³)
Liquid
1 to 10,000 mPa · s dynamic viscosity
ø < 5 mm (0.2 in)
Lateral loading capacity of the tuning fork: max. 200 N
0
+50
+100
+90
+32
+122
+212
+194
Liquiphant FTL33
1
2
[°C]
+150
[°F]
+302
Endress+Hauser
T
P
A0020869

Werbung