Herunterladen Diese Seite drucken

Endress+Hauser Liquiphant FTL33 Bedienungsanleitung Seite 59

Vorschau ausblenden Andere Handbücher für Liquiphant FTL33:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Liquiphant FTL33
Valve plug, cable
Depending on the assignment of the connector or the wiring of the cable, the device works in
either the MAX or MIN operating mode.
When the cable is wired, one wire of the cable does not have any function in each of the
operating modes (gray in the case of MAX, and brown in the case of MIN). The cable with no
function must be secured against inadvertent contact.
Electrical connection
Valve plug
Cable
Core colors:
1 = BK (black)
2 = GR (gray)
3 = BN (brown)
Ground = GNYE (green-yellow)
Yellow LED (ye) not lit
Yellow LED (ye) lit
K
external load
Endress+Hauser
MAX
1
>20 V
0.5A
A0022900
L1/L+
1
1
2
0.5A
L1/L+
A0022902
1
1
Operating mode
3
K
N/L–
A0021219
3
3
A0021418
3
1
>20 V
K
N/L–
A0022161
3
3
A0021418
Electrical connection
MIN
1
2
>20 V
K
0.5A
L1/L+
N/L–
1
2
1
2
3
2
1
>20 V
K
0.5A
N/L–
L1/L+
1
2
1
2
A0021220
A0021420
A0022225
A0021420
59

Werbung

loading