Error messages

4.1 Displayed error messages 3:
An error message signals an electrical defect of the
system.
The control is no longer ready-to-operate:
1. Write down the error message.
2. Switch off the main fuses of the control in
the fuse box.
3. Contact customer service.
4. Mark the control as being defective.
Using the following displayed error messages 3 you
can inform customer service of possible errors/de-
fects.
The error messages mean:
E-F1:
short in line / break in
line/ stove sensor defective
E-F2:
short in line / break in
line / bench sensor defective.
E- 12:
break in line or defective
overtemperature protector.
E-P I:
damage of the potentiometer 4 for
temperature setting
E-P 2:
damage of the potentiometer 6 for
steam setting
4.2
Red signal lamp 2 flashes:
Automatically, the control will turn off the heater if the
overtemperature protector has responded.
The control is no longer ready-to-operate:
1. Shut off the main fuses of the control in the fuse
box.
2. Contact customer service.
3. Mark the control as being defective.
WE DO IT FIRST.
Instructions for use for the user
5
Turning on / off the control and
the interior lighting
5.1 Turning on the control
WARNING - Fire hazard:
Prior to turning on the sauna control and
when selecting the start-time (time until the
stove starts) make sure that no combustib-
le objects have been placed on top of the
stove.
1. Turn on the control with the ON / OFF key 8.
A self-test follows:
• Briefly, the signal lamps 1 / 2 light up.
• A buzzer will beep once.
• The display 3 flashes: 00.00
• The control is ready-to-operate.
5.2 Turning off the control
1. After finishing the sauna / steam bath press the
ON / OFF key 8.
• The signal lamps 1 / 2 go out.
• The control has been turned off.
5.3 Turning the sauna interior lighting
on / off
1. Key 1 turns sauna interior lighting ON / OFF.