4. Error
types>
E14 QC1 Blocked
(Only gas ovens)
E15 QC1 Fault
(Only gas ovens)
E16 QV Blower Fault
(Only gas ovens)
E17 QV Blocked
(Only gas ovens)
E18 QV Fault
(Only gas ovens)
E19 QC2 Blower Fault
(20-tray gas ovens only)
E20 QC2 Blocked
(20-tray gas ovens only)
E21 QC2 Fault
(20-tray gas ovens only)
E22 COM Error
E23 Autotest Error
(Only CP and CPW)
E24 Calibration Error
(Only CP and CPW)
E25 Flow Meter Error
(Only CP and CPW)
E26 Level Error
(Only CP and CPW)
E27 Boiler Error
(Only CP and CPW)
E28 Detergent Pressure
Switch Error
(Only liquid detergent
kit)
Chamber ignition control blocked. This
error is generated when the chamber
burner does not light after 3 attempts.
Fault in the ignition box due to one of
these 2 errors:
EV gas is not activated.
The box cannot be unlocked.
Steam blower error.
Steam ignition control blocked. This error
is generated when the steam burner does
not ignite after three attempts.
Fault in the boiler ignition box due to 2
errors:
EV gas is not activated.
The box cannot be unlocked.
QC2 chamber blower error.
Chamber ignition control blocked. This
error is generated when the chamber
burner does not light after 3 attempts.
Fault in the ignition box due to one of
these 2 errors:
EV gas is not activated.
The box cannot be unlocked.
Communication error between cards.
The value of the thermocouple has not
stabilised within 15 minutes during the
autotest cycle (TC).
The value of the thermocouple has not
stabilised within 15 minutes during the
calibration cycle (TC and TN1).
A level is reached during filling after the
automatic emptying process but the flow
meter does not detect the level.
The flow meter counts more litres than it
should and no level is detected when
filling after the automatic emptying
process.
VDV has been active longer than it should
be in either of the two TG cooling
systems.
The pressure switch detects that the hose
is obstructed during the dosing of liquid
detergents.
The oven is completely disabled.
The oven is completely disabled.
Can only be operated in
Convection mode.
Can only be operated in
Convection mode.
Can only be operated in
Convection mode.
The oven is completely disabled.
The oven is completely disabled.
The oven is completely disabled.
The oven is completely disabled.
Autotest error message.
Calibration error message.
Flow meter error message.
Can only be operated in
Convection mode.
Can only be operated in
Convection mode.
Only solid detergent can be used
for washing.