4. Error
types>

4. Error types

When an error occurs:
The buzzer sounds intermittently.
The edge of the TFT flashes red.
The code and the description of the error appear on the oven display. If the control button is
pressed, the error message disappears.
Call the Fagor Technical Service to correct the error. Some functions remain enabled
depending on the error that has occurred.
This appliance is for professional use only and must be operated by qualified personnel.
The following is a list of the errors that may occur in the oven, indicating the message that will be
displayed in each case and the consequences that it will have for the operation of the oven.
Error
E1 TC Sensor
E2 TN Sensor
E3 TV Sensor
(Only 0623)
E4 TG Sensor
(Only CP and CPW)
E5 NTC Sensor
E6 Humidity Sensor
E7 High Temp.
E8 High Temp.
E9 Low Water
(Only CP and CPW)
E10 Emptying Error
(Only CP and CPW)
E11 CV Fault
(Only CP and CPW)
E12 CC Fault
E13 QC1 Blower Fault
(Only gas ovens)
Description
Chamber sensor damaged.
TC is out of range. [-10ºC.400ºC].
Core sensor (TN) damaged.
TN is out of range [-10ºC.400ºC].
Steam sensor (TV) damaged.
TV is out of range [-10ºC.400ºC].
Can only be operated in Convection mode.
Generator sensor damaged. TG is out of
range [-10ºC.400ºC].
NTC sensor damaged. NTC is out of
range [-10ºC.400ºC].
Humidity sensor damaged (HR).
HR sensor is out of range.
The controller NTC reaches 60ºC, but
does not exceed 70ºC.
The controller NTC exceeds 70ºC.
It is detected that VDV has been running
for 7 minutes or more and the maximum
level has not been reached.
It is detected that VAC has been running
for 1 minute or more and has not dropped
below the minimum level.
TG<80ºC when CV is active and TG does
not rise 3 degrees or more within 10
minutes.
CC is active and TC does not rise 3 or
more degrees within 25 minutes.
(If TC< (Setpoint -10)).
QC1 chamber blower error.
Consequence
The oven is completely disabled.
The delta function is disabled.
Can only be operated in
Convection mode.
Can only be operated in
Convection mode.
The fan (VE) will switch to full
speed.
The oven is completely disabled.
The oven operates normally. The
message is displayed for 3''
every 30''.
The oven is completely disabled.
Can only be operated in
Convection mode.
Can only be operated in
Convection mode.
Can only be operated in
Convection mode.
The oven is completely disabled.
The oven is completely disabled.