installation
116

General

Only a qualified electrician should connect the hob to the mains supply!
The installation should be performed in accordance with the applicable national
and local regulations. Damage caused by improper installation or connection is
not covered by the guarantee.
Safety instructions
For the appliance to work well, it is important:
That there is sufficient ventilation to allow the hob to cool down, in
I
accordance with the possibilities specified in this chapter.
The ventilation air drawn in by the hob must not be warmer than 35 °C. Bear
I
this in mind if the oven is to be built in under the hob.
I
That the connecting cable hangs freely and is not caught by a drawer.
The worktop is flat.
I
If the hob is to be built in any nearer than 40 mm from an adjacent wall or
I
kitchen cabinet, either to the back or side of the appliance, the wall or
cabinet should be lined with a heat resistant material.
installation
117

Overall dimensions

A certain height under the worktop is necessary if the hob is installed above an
oven. This height under the worktop depends on the following:
Worktop thickness;
I
I
Installed height of the hob (56 mm);
Height of oven at highest point (not including the operating panel).
I
The required height under the worktop is the height of the oven at the highest
point plus the installed height of the hob less the worktop thickness.
Space to be left free around the appliance:
774
522
56
750
490
Worktop thickness
Installed height
of the hob
Height under
the worktop
Height of oven
at highest point

Werbung