5.7

Checking suction valve

In order to access the intake valve, the air filter has to be removed in accordance with
section 5.4.
Then open the air throttle by hand, ensuring that it has a smooth stroke and can be
opened fully. If the air throttle jams or doesn't operate fully, then replace the valve with a new one.
5.8

Servicing bearings of electric motor

When the compressor is used, fresh viscous lubricant (formulated for rolling bears) should be
added to the motor's bearings. Lubricant should be added using a special syringe for viscous
lubricants through lubricators accommodated in the motor's bearing caps. The volume of lu-
bricant added can be calculated using the formula:
D 2
motor shaft
Do not over-lubricate the bearings beyond the standard level as all excess lubricant will be
squeezed out of the bearings into the motor when the motor is running.
6.

Fault handling

6.1

Faults and corrective actions

Problem
The compressor starts up with
lag. There is a slow build up in
the electric motor's speed.
The compressor won't start.
There's a temperature block on
the control unit's display.
The compressor is overheating.
The safety-relief valve of the
separator tank is activated.
COMPRAG
Screw air compressor DV-Series
(mm) х 0,005 = М
Possible faults
The oil is thick.
The ambient air temperature in
the facility does not meet the
required temperature (below
+5 °C or above +40 °C).
There's insufficient ventilation in
the facility where the compres-
sor is installed.
The oil level is too low.
The radiator is dirty
The separator is dirty.
The pressure is too high
(over13 bar).
(lubricant mass)
Corrective actions
Replace the oil.
Ensure the necessary ambi- ent
air temperature where the com-
pressor is installed.
Increase the air circulation
inside the facility.
Top up oil.
Blow down the radiator with
compressed air.
Perform maintenance by
replac- ing the separator.
Set the working pressure
below 13 bar.
(g).