Switch on the voltage. Open the air outlet valve. Press button
el. The compressor starts running in an automatic operation mode, controlled by the v-Log
electronic controller.
4.3

Switching off the compressor

Press button
"Shutdown" on the control panel. The compressor stops. LCD display is
switched off. Close the air outlet valve. Switch off the voltage.

5. Maintenance

5.1

Maintenance schedule

Maintenance schedule
Oil level
Compressor oil
Air filter
Oil filter
Ait-Oil Separator
Heat exchanger
Bearings of electric
motor
Intake valve
Minimum pressure
valve
Safety valve
Beyond 6000 working hours, compressor maintenance consists in alternating M-2 and M-3
every 2000 hours of running time. Performance of daily, weekly, monthly and annual servic-
ing does not annul the need for maintenance in terms of operating hours.
COMPRAG
Screw air compressor DV-Series
To stop the compressor in the case of emergency, press the emer-
gency stop button on the control panel.
After remedying the fault, unlock the button by pulling it out before
restarting.
After emergency shutdown of the compressor, it can only be re-
started again no sooner than 10 minutes later.
Daily
Monthly
Check/
Refill
Cleaning
Cleaning
Yearly
M-1
500
Replace
Replace
Lubricate
Check
Check
Check
"Start" on the control pan-
Interval in work hours
M-2
M-3
2000
4000
Replace
Replace
Replace
Replace
Replace
Replace
Replace
M-2
6000
Replace
Replace
Replace
27