Er:3137 R
controller will allow motor start when pressure decreases below the set level, see blowdown
timeout E0814
6. Service Alarms
6.1 Special function service alarms
Er:4804 A
timer)
4.3

Starting the compressor

Switch on the voltage.
Open the air outlet valve.
Press button
"Start" on the control panel.
The compressor starts running in an automatic operation mode, controlled by the pro-Log
electronic controller.
4.4

Switching off the compressor

Press button
"Shutdown" on the control panel.
The compressor stops. LCD display is switched off.
Close the air outlet valve.
Switch off the voltage.
COMPRAG
Screw air compressor A-Series
Internal pressure PI higher than the set run inhibit pressure level,
Service hours time expired, service due (reset service hours countdown
Before staring check oil level at sight glass on the Air-Oil separa-
tion tank.
To stop the compressor in the case of emergency, press the emer-
gency stop button on the control panel.
After remedying the fault, unlock the button by pulling it out before
restarting.
After emergency shutdown of the compressor, it can only be re-
started again no sooner than 10 minutes later.