Charger for TC-CT 3.6 Li
Battery charge voltage: ............................. 5 V DC
Battery charge current: ............................ 400 mA
Charging unit
supply voltage: ....................100-240V ~ 50/60 Hz
Charging time: ......................................3 - 5 hours
Hazard!
Sound and vibration
Sound and vibration values were measured in ac-
cordance with EN 60745-1 and EN 60745-2-16.
L
sound pressure level ........................ 81 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level .......................... 92 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) were determined in accordance with EN
60745-1 and EN 60745-2-16.
Vibration emission value a
K uncertainty = 1.5 m/s
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Anl_TC_CT_3_6_Li_SPK7_Kit.indb 14
Anl_TC_CT_3_6_Li_SPK7_Kit.indb 14
= 3.436 m/s
2
h
2
- 14 -
GB
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.

5. Before starting the equipment

Hazard!
Charge the battery only with the charging unit
supplied.
5.1 Charging the battery (Fig. 2)
The battery is protected from exhaustive dischar-
ge. An integrated protective circuit automatically
switches off the equipment when the battery is
fl at.
Note! Do not actuate the On/Off switch any more
if the protective circuit has tripped. This may da-
mage the battery.
Check that your mains voltage is the same as that
marked on the rating plate. Plug the battery char-
ger (6) in the plug socket and connect the char-
ging cable (5) to the charging connection (a). The
charging process starts as soon as the charging
cable is connected to the charging adapter.
The red LED on the indicator (7) indicates that the
battery is being charged. When the charging has
fi nished, the red LED will go out and the green
LED will begin to shine.
If the indicator (7) fl ashes red and green alterna-
tely, this means that the temperature is too low or
high. Keep the tool at room temperature for a day
and try again.
If the indicator (7) continues to fl ash red and
green alternately, the battery is defective. A defec-
tive battery is not allowed to be used any more.
24.05.16 15:29