TROUBLESHOOTING

Most of the times apparent inconveniences are caused by distractions or a non-workmanlike installation. However, below is
shown what to do in the most frequent cases.
1) In case of smoke emissions, make sure that:
The smoke valve is open enough.
The air inlet adjustment lever is open enough.
The installation has been carried out correctly (smoke duct, flue, chimney pot).
The wood is dry.
2) In case of uncontrolled combustion, make sure that:
The smoke valve is not too open
The door seals are in place.
The firebox door is tightly closed.
3) In case the glass gets easily dirty, make sure that:
The wood is dry.
The smoke valve is always open at least by 25-30%
However, keep in mind that after a few hours of operation, it is normal that a a slight layer of dust deposits on the glass.
In the event the inconvenience cannot be solved, please contact your dealer.