CB, RHD
➤ Determine the required cross section of the cable in relation to the cable length
according to fig. 4, page 4.
Key for fig. 4, page 4
Co-ordinate axis
l
A
NOTICE!
Make sure that the polarity is correct.
➤ Connect the red lead to the positive terminal.
➤ Connect the black lead to earth.
➤ Before starting up the device for the first time, check whether the operating volt-
age and the battery voltage correspond (see type plate).
➤ Connect the cooling device
– As directly as possible to the pole of the battery or
– To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at 24 V).
A
NOTICE!
Disconnect the cooling device and other power consuming devices
from the battery before connecting the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
The cooling device is equipped with an electronic device to protect against
reversing the polarity and short circuits when connecting to a battery.
To protect the battery, the cooling device switches off automatically if the voltage is
insufficient (see table below).
Switch-off voltage
Switch-on voltage
EN
Installing and connecting the cooling device
Meaning
Cable length
Cable cross section
Unit
m
mm²
12 V
10.4 V
11.7 V
24 V
22.8 V
24.2 V