6.2 Digital 24 V inputs / outputs

6.2.1 Digital Inputs

Digital inputs
Tab. 5:
Plug
Bits
Inputs
Fuse monitoring – FC6
XGD1
0
Fuse moniotring – FC7
1
Speed tip dresser 1
2
Swiveling device tip dresser 1 back
3
Swiveling device tip dresser 1 front
4
Monitoring motor protection switch –
5
QA2 gun drives
Stroke cylinders tip dress 1 swiveled
6
in/out position
7
Monitoring motor protection switch –
QA4 dresser drives
XGD2
8
Operating protection
9
+24V detection 3-fold cabinet
10
Fuse monitoring – FC2
Overload -FC3
11
Welding release, drive release
12
Fuse monitoring – FC1
13
Power circuit breaker ON
14
No ground fault current
15
Byte
Bit
PRC7000 inputs
27
0
ASCII_9, Bit_0
27
1
ASCII_9, Bit_1
27
2
ASCII_9, Bit_2
27
3
ASCII_9, Bit_3
27
4
ASCII_9, Bit_4
27
5
ASCII_9, Bit_5
27
6
ASCII_9, Bit_6
27
7
ASCII_9, Bit_7
Description
Load monitoring in the cabinet
Load monitoring in the cabinet
Not used
Not used
Not used
Circuit braker in the cabinet
Not used
Circuit braker in the cabinet
is to be assigned with US2 signal (safety door contact)
 0V: No gun movement via internal servo gun control allowed
 - 24V: Gun movement via internal servo gun control allowed
Not used
Load monitoring in the cabinet
Load monitoring in the cabinet
Drive and weld on
Load monitoring in the cabinet
Switch power on
Make sure that the system is switched on but is not involved in any
production process and check all protective devices of the system
(e.g. residual current monitoring, emergency stop) for correct function.
Bosch Rexroth AG | Electric Drives and Controls
PRC7000 outputs
45/58

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis