Herunterladen Inhalt Inhalt Diese Seite drucken

Function Description Of Prc7000 Outputs - Bosch Rexroth PRC 7 00L Serie Typspezifische Anleitung

Vorschau ausblenden Andere Handbücher für Rexroth PRC 7 00L Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

48/56
Bosch Rexroth AG
No.
PRC7000 inputs
108..111
Tool Bit 00..03
112..115
Factory Bit 00..03
116..119
Construction Bit 00..03
120..123
Model Bit 00..03
124..127
L/R- steering wheel Bit 00..03
128..131
Type Bit 00..03
132..141
Model range Bit 00..09
142, 143
-
144..223
ASCIIByte0 Bit 0
.
.
ASCIIByte9 Bit 7
No.
PRC7000 outputs
0
Data for spot selection valid
1
No timer stop [VISUxxx0.0S]
2
Weld complete
3
Timer ready [VISUxxx1.7S]
4
Welding fault
5
-
Description
Spot extension: inputs for selecting the second fragment of spot
selection
Spot extension: inputs for selecting the third fragment of the spot
selection
Spot extension: Inputs for selecting the fourth fragment of the spot
selection
Spot extension: Inputs for selecting the fifth fragment of the spot
selection
Spot extension: Inputs for selection of the sixth fragment of the spot
selection
Spot extension: Inputs for selection of the seventh fragment of the
spot selection
Spot extension: inputs for selection of the eighth fragment of spot
selection
without function
• 8 characters component identifier (ASCII coded); ASCIIByte0 is
interpreted as first character
• The part identifier is read from these fieldbus inputs at the start of a
welding cycle and entered in the actual value log.
7.2

Function description of PRC7000 outputs

Function description of PRC7000 outputs
Tab. 13:
Description
• Handshake signal to "new spot selection " input
• Details see "New spot selection"
There is no emergency/stop
Is set if the heatsealing cycle was completed without errors.
Remains set as long as input "Program start" is set.
• If input "Program start" is no longer set at the end of the
heatsealing cycle, this output is set for the programmed FK
duration [ca. 50ms].
For details, see "Program start
The system reports that the control part of the system is ready
and does not report any errors. This signal does not include the
status of the servo gun, which may be in a state not ready for
welding (e.g.: gun is undocked).
• This output is set if a heatsealing sequence was aborted or
• ended with a welding fault.
• For details see "Program start"
Without function
R911407348 | PRC 7x00-Lx/Wx-1300

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis