4 Installation

This amplifier is built for 19" racks (483 mm) but can also be used as a tabletop unit. In order to ensure
sufficient cooling of the amplifier, air must always be able to flow freely through all air vents. For rack
installation, the amplifier requires 2 U. If several units are to be installed, make sure that you leave 1 unit
space between the devices. Insert the heaviest units into the lower part of the rack. The hot air given off by
the amplifier must be dissipated from the rack; otherwise heat will accumulate in the rack which may not only
damage the amplifier but also other units in the rack. In case of insufficient heat dissipation, install a
ventilation unit into the rack.

5 Connections

High voltage at terminals when using PA systems. Installation by skilled personnel only! Turn off
amplifier before connecting.
For connecting speakers direct outputs (these are not affected by the zone buttons) and zone outputs are
available. The direct outputs and the zone outputs are connected in parallel. The total load must not exceed
60 W
(MAVZ-60P.6), 120 W
RMS
otherwise the amplifier may be damaged by overload.

Zone outputs

For the six PA zones, PA speakers with 100 V audio transformer can be connected to the "100 V SPEAKER
ZONE OUTPUT" terminals. When connecting, observe the correct polarity (positive and negative
connections). The positive connection of the speaker cables is always specially marked.
DANGER TO LIFE!
(MAVZ-120P.6), 240 W
RMS
21 • EN
(MAVZ-240P.6) or 360 W
RMS
(MAVZ-360P.6)