Herunterladen Inhalt Inhalt Diese Seite drucken

Programmable Rain Off; Bypass Weather Sensor; Seasonal Adjustment; Manually Run A Single Station - Hunter EC Bedienungs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für EC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59

Programmable Rain Off

This feature permits the user to stop all pro-
grammed waterings for a designated period from
1 to 7 days. At the end of the programmable rain
off period, the controller will resume normal
automatic operation.
1. Turn the dial to the SYSTEM OFF position.
Wait for OFF to be displayed.
2. Press
as many times as needed to set
the number of days off desired (up to 7).
3. Turn the dial back to the AUTOMATIC position at
which time, OFF, a number and the DAYS icon
all remain on.
The days off remaining will decrease at midnight
of each day. When it goes to zero, the display will
show the normal time of day and normal irrigation
will resume at the next scheduled start time.

Bypass Weather Sensor

If the weather sensor is interrupting irrigation, you can bypass it by
using the manual watering options described below. The dial positions
MANUAL-ONE STATION and position MANUAL-ALL STATIONS as well
as the One Touch Start and Advance process will successfully bypass
the rain sensor.

Seasonal Adjustment

Seasonal Adjust is used to make global run time changes without
re-programming the entire controller. To use the seasonal adjustment
feature:
1. Turn the dial to the SEASONAL
ADJUSTMENT position.
2. The display will now show a flashing number followed by a %, as
well as the bar graph which always remains on the display. Press
the
or
buttons to adjust the percentage of the seasonal ad-
justment. Each bar on the graph represents 10%. This feature can
adjust the controller from 10% to 150% of the original program.
9
To view the new adjusted run times, simply turn the rotary dial to
SYSTEM OFF
the SET STATION RUN TIMES position, the displayed run time will be
updated accordingly as the seasonal adjustment is made.

Manually Run a Single Station

1. Turn dial to the MANUAL-ONE STATION position.
AUTOMATIC
2. Station run time will flash in the display. Use the
3. Turn the dial clockwise to the AUTOMATIC position to run the sta-

Manually Run All Stations

1. Turn dial to MANUAL-ALL STATIONS.
2. Select program A, B, or C by pressing the
3. Press the
4. Station run time will flash in the display. Use the
5. Use the
6. Repeat steps 3 and 4 to customize
SEASONAL ADJUSTMENT
7. Press the
NOTE: The controller should always be initially pro-
grammed in the 100% position.
move to the desired station. You may use the
select the amount of time for a station to water.
tion (only the designated station will water, then the controller will
return to automatic mode with no change
in the previously set program). Also see
One Touch Manual Start and Advance on
page 10.

ALL

button until desired starting station is displayed.
to select the amount of run time for the station to water if different
from the run time displayed.
button to move to the next station.
each station if desired.
button until you reach the
station that you would like watering to begin.
1
button to
or
button to
MANUAL-ONE STATION
1
button.
or
button
MANUAL-ALL STATIONS
ALL

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis