TROUBLESHOOTING GUIDE (cont.)
PROBLEM
Automatic irrigation does not start at
start time and controller is not in the
system off mode.
Controller waters the same area
more than one time/Controller cycles
continuously.
SPECIFICATIONS
Operating Specifications
•
Station Run Time: 0 to 4 hours in 1-minute increments.
•
Start Times: 4 per day, per program, for up to 12 daily starts.
•
Watering Schedule: 7-day calendar or interval (1 to 31 day)
programming.
•
AM/PM or 24 hour clock option.
•
Start time stacking.
•
Simple manual operation, including 1 button manual operation.
•
Seasonal Adjustment: 10 to 150% in 10% increments.
Electrical Specifications
•
Transformer Input: 230/240VAC, 50/60Hz International Use.
•
Transformer Output: 24VAC, 0.625 Amps.
•
Station Output: 24VAC, .28 Amps per station.
CAUSES
AM/PM of time of day not set correctly.
AM/PM of start time not set correctly.
Start time is disabled (Set for Off).
Controller is not receiving AC power.
Too many start times entered in program
(user error).
SOLUTIONS
Correct AM/PM of time of day.
Correct AM/PM of start time. Set start time.
See "Setting Watering Start Times".
Check AC connections.
One start time activates a complete cycle.
See "Setting Watering Start Times".
•
Maximum Output: 24VAC, .56 Amps.
•
Master Valve Output: 24VAC, .28 Amps.
•
Battery: Not required for program backup. 9-volt alkaline battery
(not included) may be used to program controller in absence of
AC power.
•
Electronic short circuit protection.
•
Surge protection: primary MOV-type.
•
Non-volatile memory for program data.
•
Controller will track time for 4 weeks in event of a power outage
(even without a 9 volt battery).
•
Rain sensor override by manual operation.
ENG
12