Herunterladen Inhalt Inhalt Diese Seite drucken

Wilo Yonos PICO OEM Einbau- Und Betriebsanleitung Seite 27

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical data
Connection voltage
Protection class IP
Energy efficiency index EEI
Fluid temperatures at
max. ambient temperature +40 °C
Fluid temperatures at
max. ambient temperature +25 °C
Permitted ambient temperature
Max. operating pressure
Min. inlet pressure at +95 °C/+110 °C
LED display
Operating button
Installation and operating instructions Wilo-Yonos PICO OEM
• Display of the current power consumption in W.
• Display of the setpoint H of the delivery head
(differential pressure) in m.
• Display of selected constant speed
(c1 = I, c2 = II, c3 = III).
• Display of warning and fault signals.
3.1
Controls
Turn
• Select application/control mode.
• Set setpoint H of the delivery head (differential pres-
sure).
• Select constant rotation speed.
1 ~ 230 V ± 10 %, 50/60 Hz
See rating plate (4)
See rating plate (4)
-10 °C to +95 °C
-10 °C to +110 °C
-10 °C to +40 °C
10 bar (1000 kPa)
0.3 bar/1.0 bar (30 kPa/100 kPa)
27