DISPOSAL OF OUTDOOR UNIT DRAIN WATER
• When a Drain elbow 1 is used, please ensure to follow below:
- the unit should be placed on a stand which is taller than 50 mm.
- cover the ø20mm holes with Rubber cap 2 (refer to illustration below).
- use a tray (fi eld supply) when necessary to dispose the outdoor unit drain water.
• If the unit is used in an area where temperature falls below 0°C for 2 or 3 consecutive days, it is recommended not to use the Drain elbow 1
and Rubber cap 2 , for the drain water freezes and the fan will not rotate.
2
Rubber cap
INSTALL THE DISCHARGE GRILLE
3
This section is for WH-UDZ05KE5*, WH-UDZ07KE5* and
WH-UDZ09KE5* only.
Make sure to install the outdoor unit on concrete or rigid frame by
bold nut before install the discharge grille 3.
Hook the metal plate 4 on the cabinet front plate at 2 locations
and tighten with screw 5. (Figure a)
Hook the discharge grille 3 to the cabinet front plate at 4 locations.
(Figure b)
x 2
8
Drain elbow
x 7
WH-UDZ03KE5*
Figure a
x 4
1
2
Rubber cap
WH-UDZ05KE5*, WH-UDZ07KE5* and WH-UDZ09KE5*
Tighten the discharge grille to the cabinet front plate at 6 locations
with screw 5. (Figure c)
Make sure to install the discharge grille to the outdoor unit
before powering ON to protect againts a rotating fan
x 4
Figure c
Drain elbow
x 3
CAUTION
Figure b
x 2
1