PROGRAMMING STRINGS
3.5 HOW TO PROGRAM AN ID-NET™ SLAVE READER
An ID-NET™ Slave (Multidata) #N can be configured through the Master (Multidata) device
"encapsulating" the same Host Mode
a special command with the following format:
Where:
ADDR:
STRING:
ADDR is a character indicating address of the device in an ID-NET™ Master/Slave reading
system layout:
ADDR = <30
> + <Device Address> where:
H
Device Address = 0:
Device Address = 1 to 31:
This means:
ADDR = <30
>:
H
ADDR = <31
> to <4F
H
If the programming is correct, the Slave device sends to the Master with the following
message:
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the Slave device replies with the following message and programming data will not be
updated in this case:
After transmitting the proper reply message, the Slave device then waits for one or more
programming strings or the exit from host mode command.
3.6 HOW TO GET SINGLE PARAMETER FROM AN ID-NET™ SLAVE
READER
Programming Commands
<ESC> ( <B0
> ADDR STRING ) <ESC>
H
Device Address
Programming Command/String To Send (Length: 1 to 1042)
Standalone device or Master Multidata ID-NET™ device
Slave Multidata ID-NET™ device
Standalone device or Master Multidata ID-NET™ device
>:
Slave Multidata ID-NET™ device
H
<ESC> K <CR><LF>
<ESC> W 1 <CR><LF>
and
Programming Strings