Herunterladen Inhalt Inhalt Diese Seite drucken

SOLIS GRIND & INFUSE PERFETTA Schnellstartanleitung Seite 26

Inhaltsverzeichnis

Werbung

M O N T H LY M A I N T E N A N C E
V
We recommend cleaning the appliance every month. To clean the appliance:
1.
Plug in and switch on the appliance.
2.
Set the grind size selector
to COARSE.
g
3.
Close the hopper gate at the back of the bean container 1.
4.
Place a container under the portafilter holder 3.
5.
Press the grind time knob
to switch on the grinder and remove excess coffee.
c
6.
After a few seconds, press the grind time knob
7.
Switch off the appliance and remove the bean container
Empty the bean container 1.
8.
Always remove the bean container (see image E) first and only then remove
6
the grinder mechanism. Do not take off both parts together and never use
excessive force to remove the parts.
Reassemble the bean container
9.
(see image F).
1
10. Fill the bean container
with GRINDZ
which is available in selected countries.
TM
1
You can buy GRINDZ
at your supplier or Solis (art. No. 993.08).
TM
4
11. Open the hopper gate at the back of the bean container 1.
12. Place a container under the portafilter holder 3.
13. Switch on the appliance.
14. Press and hold the grind time knob
to switch on the grinder.
c
15. When all GRINDZ
has run through the appliance, release the grind time knob
TM
grinder.
16. Close the hopper gate.
17. Switch off the appliance and remove the bean container
18. Empty the bean container 1.
19. Rinse the bean container
with warm water and a mild detergent.
1
20. Rinse the bean container
with clean water.
1
21. Dry the bean container
thoroughly.
1
22. Reassemble the grinder and the bean container 1. Make sure all parts lock in place.
23. Fill the bean container
with coffee beans.
1
24. Open the hopper gate at the back of the bean container 1.
25. Switch on the appliance.
26. Press and hold the grind time knob
to switch on the grinder.
c
27. After 20 seconds, release the grind time knob
28. Set the grind size selector
back to the desired position.
g
29. Switch off and unplug the appliance.
Make sure the portafilter is not hot when removing the spout.
4
30. Unscrew the spout of the portafilter s.
31. Soak the following parts in warm water and a mild detergent:
Portafilter
(only the metal parts).
s
Cup filters
p a
Spout
32. Unscrew the steaming nozzle from the steaming wand 5.
46
again to switch off the grinder.
c
(see image E).
1
to switch off the
c
(see image E).
1
again to switch off the grinder.
c
If the nozzle opening is blocked, you can use the pin on the cleaning tablet holder to remove the
4
blockage. If you cannot unblock the nozzle with the pin, rinse the nozzle with warm water and try
again.
33. Rinse the nozzle in warm water.
34. Gently screw the nozzle back onto the steaming wand 5.
35. Clean the appliance and the water tank
8
36. Dry the appliance and the water tank 8.
37. Plug in and switch on the appliance.
R E P L AC I N G T H E WAT E R F I LT E R C A R T R I D G E
V
Replace the water filter cartridge when the corresponding alarm is visible.
1.
Switch off and unplug the appliance.
Remove the water tank
2.
from the appliance (see image G).
8
Empty the water tank
3.
above a sink.
8
Remove the water filter cartridge
from the water tank 8.
4.
9
Hold the new water filter cartridge
5.
in a container with water.
9
Use the INTENZA water filter cardridge (Art.-no. 700.78) which is available in selected countries.
4
6.
Gently squeeze the water filter cartridge
7.
Rinse the water tank
with water.
8
8.
Insert the water filter cartridge
into the bracket in the water tank
9
downwards.
9.
Fill the water tank
with water up to the MAX marking.
8
10. Insert the water tank
into the appliance.
8
11. Place a container (min. 500 ml) underneath the brewing head 4.
12. Plug in and switch on the appliance.
13. Press the programming button d.
14. Press the single cup extraction button
j
When the appliance beeps twice and the cup extraction buttons light up white, the appliance is ready for
use.
U S I N G T H E B R E W I N G H E A D C L E A N I N G C YC L E
V
Clean the appliance with a cleaning tablet when the corresponding alarm is visible.
For cleaning the brewing head, please use a cleaning tablets which are suitable for espresso machines.
For best results, we recommend SOLITABS (Art.-no. 993.02) which is available in selected countries.
4
To clean the appliance with a cleaning tablet:
1.
Plug in and switch on the appliance.
2.
Place the double cup filter
into the portafilter s.
p
3.
Place the rubber insert for cleaning
into the double cup filter
i
SOLITABS cleaning tablet on top.
Insert and rotate the portafilter
into the brewing head
4.
s
is aligned with the CLOSE marking.
Place a container underneath the portafilter s.
5.
Press the programming button d.
6.
Press the double cup extraction button
7.
k
The procedure has 8 cycles with pauses of 30 seconds. The cycle number and pause time are shown on
the display.
with a soft and damp cloth.
to remove air bubbles from the filter.
9
with the selector facing
8
to activate the automatic rinsing cycle.
(see image H) and put a
p
(see image C). Make sure the handle
4
to start the rinsing procedure.
47

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1019

Inhaltsverzeichnis