Prior to mounting
S Care should be taken to ensure that all surfaces for siting and mounting are
clean, smooth and level. Depending on the mounting conditions, any level
ing error can be compensated for by using suitable wedges and compensa
tion plates (permanently welded) or by grinding away the mounting surface,
for example. On no account must the module plates be ground.
S The base or foundation frame must be sufficiently rigid to prevent unaccept
able deformation under load (such as sagging).
S In order to keep the mounting as free of constraining forces as possible, the
fastening holes on the foundation frame and container joint must be suitably
aligned.
S Every effort should be made to ensure uniform loading on the support
points. Care should be taken to adjust the height on the support points cor
rectly (compensating shims need to be available). This is especially impor
tant in the case of statically undefined supports.
Z6AM
A01559_03_Y00_00 HBM: public
Prior to mounting