Mounting instructions

4
Mounting instructions
S lt should be ensured that the mounting/siting surfaces are clean, flat and
level. Depending on the Installation circumstances, any levelling error can
be compensated for example by suitable wedges and compensating plates
(permanently welded) or by the grinding away the mounting surface. On no
account must the module plates be ground.
Notice
On no account must the module plates be ground.
S The foundation/base frame must be sufficiently stiff so that no impermissi­
ble deformations (e.g. deflections) occur on loading.
S In order to keep the mounting as free of straining forces as possible, the
fastening holes on the base frame and the tank joint must be sufficiently in
alignment. Same means to the bore of the anti‐liftoff device.
S Uniform loading on the support points should be provided where possible.
Correct adjustment of the height on the supporting points must be ensured
(have compensating shims ready). This is especially important for statically
undefined supports.
8
A01268_04_XS0_00 HBM: public
C16M...