Herunterladen Inhalt Inhalt Diese Seite drucken

HBM Z6AM Montageanleitung Seite 19

Vorschau ausblenden Andere Handbücher für Z6AM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Type
Nennlast
Permissible dynamic load
Nominal (rated) displacement, approx.
Weight, approx.
Degree of protection according to
EN60529 (IEC529)
Material
Measuring body
Bellows
Screwed cable gland
Cable sheath
1)
The values for linearity deviation, relative reversibility error and temperature effect on sensitivity
are typical values. The sum of these values is within the cumulative error limits laid down by OIML
R60.
2)
As per EN 10088-1
Z6AM
Specifications for the Z6... load cells
A01559_03_Y00_00 HBM: public
Z6FC4
kg
100
% of
100
E
max
mm
0.31
kg
0.5
(severe test conditions: 1 m
water column;100 h)
Stainless steel
Stainless steel
Stainless steel / Viton
Z6FC6
200
500
1000
100
70
100
0.39
0.6
0.55
0.5
0.5
IP 68
2)
2)
®
PVC
2.3
17

Werbung

Inhaltsverzeichnis
loading