Herunterladen Inhalt Inhalt Diese Seite drucken

Installer Instructions - Vortice PUNTO EVO Betriebsanleitung

Punto evo - me
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
ENGLISH

Installer instructions

For some models the installer can change the factory settings:
LL
No configuration tasks for the installer
LL TP
Factory settings
- switch-off delay (dip switch): 6 min
- switch-on delay (dip switch): 45 seconds
- automatic switch-on cycle: OFF = 0 H
- 2 speeds: position A of the jumper (fig.16)
Possible settings
- Jumper setting (fig 15a,16). The motor has two operating speeds: V1 and V2. By appropriately setting the
jumpers as described in the following table A it is possible to determine which will be the maximum and
minimum speed between V1 and V2. The timer will always act on V1.
- Dip-switch settings (fig. 17). N.B. Before making any changes to the dip-switches, disconnect the electric
power supply. It is possible to configure the time lag for switching on/off, (see under Use), by appropriately
setting the 6 dip-switches as described in the following table:
0 sec.
OFF
45 sec.
ON
T
A
90 sec.
OFF
120 sec.
ON
6 min.
--
10 min.
--
T
B
15 min.
--
21 min.
--
0 hr.
--
8 hr.
--
T
C
12 hr.
--
24 hr.
--
54
Int. 1
Int. 2
OFF
OFF
ON
ON
--
--
--
--
--
--
--
--
DIP switch
Int. 3
Int. 4
--
--
--
--
--
--
--
--
OFF
OFF
ON
OFF
OFF
ON
ON
ON
--
--
--
--
--
--
--
--
Int. 5
Int. 6
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
OFF
OFF
ON
OFF
OFF
ON
ON
ON