the set threshold the appliance will automatically return to the standard operation of mode 3.
Mode 4: the motor starts automatically when the sensor detects a rapid increase in humidity. The operating
speed is V1 (minimum or maximum, as set during configuration). The motor will stop when at least one of the
following conditions occurs:
• the relative humidity falls by a value of 15%RH compared to the value that caused the motor to switch on
• after 2 hours of operation.
All the variable parameters described above are configured on a value set during installation. The manual
operations can overlap the automatic ones and vice versa.
HCS OFF operation
With this configuration, you can temporarily disable the action of the humidity sensor. The function is activated
by pressing switch 1, and it turns off automatically after one hour. Instead of the switch it is possible to use a
button, which must be pressed for at least 0.5 sec.
When the function is active there is only one possible operating mode:
the motor is started and stopped manually with switch 2. The operating speed is V2 (minimum or maximum,
as set during configuration). However, when the function is not active the automations for modes 3 and 4 are
operational.
LL T PIR: on this model the PCB is connected to a PIR presence sensor. The appliance permits one operating
mode: the motor is activated at speed V (minimum or maximum, as set during configuration) by the PIR
presence sensor tripping. The motor will switch off at the end of the sensor signal, after a delay of between 3
and 20 minutes (as set during configuration, see "Instructions for the Installer).
LL T: on this model the PCB permits one operating mode: the motor starts at speed V (minimum or maximum,
as set during configuration) on pressing the switch. Pressing the switch again will switch off the motor, after a
delay of between 3 and 20 minutes (as set during configuration, see "Instructions for the Installer").