[Parameter setting]
[Parameter setting]
Title
Title
Motor electronic-thermal
Motor electronic-thermal


protection level 1
protection level 1
Electronic-thermal
Electronic-thermal
protection characteristic
protection characteristic


selection
selection
Motor electronic-thermal
Motor electronic-thermal
f173
f173
protection level 2
protection level 2
Motor 150% overload
Motor 150% overload
f607
f607
detection time
detection time
Inverter overload detection
Inverter overload detection


method
method
Electronic-thermal memory
Electronic-thermal memory




Overload alarm level
Overload alarm level
Note) (Only for -W1 model)
Note) (Only for -W1 model)
aul must be set to default setting (1: Constant torque characteristic) for the compliance with UL standard.
aul must be set to default setting (1: Constant torque characteristic) for the compliance with UL standard.
1) Setting the electronic thermal protection characteristics selection o o l l m m
1) Setting the electronic thermal protection characteristics selection o o l l m m
and motor electronic thermal protection level 1 t t h h r r , 2 f f 1 1 7 7 3 3
and motor electronic thermal protection level 1 t t h h r r , 2 f f 1 1 7 7 3 3
The electronic thermal protection characteristics selection (olm) is used to enable or disable the motor overload trip
The electronic thermal protection characteristics selection (olm) is used to enable or disable the motor overload trip
function (ol2) and the overload stall function.
function (ol2) and the overload stall function.
While the inverter overload trip (ol1) will be in constantly detective operation, the motor overload trip (ol2) can be
While the inverter overload trip (ol1) will be in constantly detective operation, the motor overload trip (ol2) can be
selected using the parameter olm
selected using the parameter olm
Explanation of terms
Explanation of terms
Overload stall: This is an optimum function for equipment such as fans, pumps and blowers with variable torque
Overload stall: This is an optimum function for equipment such as fans, pumps and blowers with variable torque
characteristics that the load current decreases as the operating speed decreases.
characteristics that the load current decreases as the operating speed decreases.
When the inverter detects an overload, this function automatically lowers the output frequency before the motor
When the inverter detects an overload, this function automatically lowers the output frequency before the motor
overload trip (ol2) is activated. With this function, operation can be continued, without tripping, by operating
overload trip (ol2) is activated. With this function, operation can be continued, without tripping, by operating
using a frequency balanced by load current.
using a frequency balanced by load current.
Note: Do not use the overload stall function with loads having constant torque characteristics (such as conveyor
Note: Do not use the overload stall function with loads having constant torque characteristics (such as conveyor
belts in which load current is fixed with no relation to speed).
belts in which load current is fixed with no relation to speed).
[Using standard motors (other than motors intended for use with inverters)]
[Using standard motors (other than motors intended for use with inverters)]
When a motor is used in the lower frequency range than the rated frequency, that will decrease the cooling effects for
When a motor is used in the lower frequency range than the rated frequency, that will decrease the cooling effects for
the motor. This speeds up the start of overload detection operations when a standard motor is used in order to prevent
the motor. This speeds up the start of overload detection operations when a standard motor is used in order to prevent
overheating.
overheating.
 Setting of electronic thermal protection characteristics selection olm 
 Setting of electronic thermal protection characteristics selection olm 
Setting value
Setting value
0
0
1
1
2
2
3
3
Function
Function
10 – 100 (%)
10 – 100 (%)
Setting
Setting
value
value
10 – 100 (%) / (A)
10 – 100 (%) / (A)
10 – 2400 (s)
10 – 2400 (s)
0: 150%-60s
0: 150%-60s
1: Temperature estimation
1: Temperature estimation
0: Disabled (thr, f173)
0: Disabled (thr, f173)
1: Enabled (thr, f173)
1: Enabled (thr, f173)
2: Disabled (thr)
2: Disabled (thr)
3: Enabled (thr)
3: Enabled (thr)
10-100
10-100
Overload protection
Overload protection
Overload stall
Overload stall
valid
valid
valid
valid
invalid
invalid
invalid
invalid
Adjustment range
Adjustment range
Overload
Overload
protection
protection
0
0
valid
valid
1
1
valid
valid
Standard
Standard
2
2
motor
motor
invalid
invalid
3
3
invalid
invalid
4
4
valid
valid
VF motor
VF motor
5
5
valid
valid
(special
(special
6
6
invalid
invalid
motor)
motor)
7
7
invalid
invalid
invalid
invalid
valid
valid
invalid
invalid
valid
valid
48
13
13
E6582383
E6582383
E6582383
Default
Default
setting
setting
100
100
Overload
Overload
stall
stall
invalid
invalid
valid
valid
invalid
invalid
0
0
valid
valid
invalid
invalid
valid
valid
invalid
invalid
valid
valid
100
100
300
300
0
0
0
0
50
50