Overload Protection - Toshiba TOSVERT VF-S15 Schnellstartanleitung

Vorschau ausblenden Andere Handbücher für TOSVERT VF-S15:
Inhaltsverzeichnis

Werbung

Terminal
Terminal
Input /
Input /
symbol
symbol
output
output
Output
Output
P24
P24
Input
Input
Input
Input
+SU
+SU
Output
Output
STO
STO
Input
Input
Note 2)
Note 2)
OUT
OUT
Output
Output
NO
NO
FLA
FLA
FLB
FLB
FLC
FLC
Output
Output
Note 3)
Note 3)
Note 4)
Note 4)
RY
RY
RC
RC
Output
Output
Note 3)
Note 3)
Note 4)
Note 4)
Note 1) When VIA terminal is used as logic input terminal, be sure to connect a resistor between P24 and VIA in case of sink
Note 1) When VIA terminal is used as logic input terminal, be sure to connect a resistor between P24 and VIA in case of sink
logic, between VIA and CC in case of source logic. (Recommended resistance: 4.7kΩ-1/2W)
logic, between VIA and CC in case of source logic. (Recommended resistance: 4.7kΩ-1/2W)
It is not needed for VIB terminal.
It is not needed for VIB terminal.
Note 2) When STO terminal is used as the safety function, refer to E6581860 "VF-S15 Safety function manual".
Note 2) When STO terminal is used as the safety function, refer to E6581860 "VF-S15 Safety function manual".
Note 3) A chattering (momentary ON/OFF of contact) is generated by external factors of the vibration and the impact, etc. In
Note 3) A chattering (momentary ON/OFF of contact) is generated by external factors of the vibration and the impact, etc. In
particular, please set the filter of 10ms or more, or timer for measures when connecting it directly with input unit
particular, please set the filter of 10ms or more, or timer for measures when connecting it directly with input unit
terminal of programmable controller. Please use the OUT terminal as much as possible when the programmable
terminal of programmable controller. Please use the OUT terminal as much as possible when the programmable
controller is connected.
controller is connected.
Note 4) OVC II: Overvoltage category II
Note 4) OVC II: Overvoltage category II

4. Overload protection

4. Overload protection
VF-S15 has overload protection.
VF-S15 has overload protection.
Over current rating: 150%-1min. 200%-0.5sec.
Over current rating: 150%-1min. 200%-0.5sec.
Refer to the nameplate for the rated current.
Refer to the nameplate for the rated current.
Refer to the instruction manual E6581610(Japanese), E6581612(Japanese) or E6582175(English) for detailed
Refer to the instruction manual E6581610(Japanese), E6581612(Japanese) or E6582175(English) for detailed
information.
information.
24Vdc power output, by changing SW1 to SINK or SOURCE side.
24Vdc power output, by changing SW1 to SINK or SOURCE side.
This terminal can be used as a common terminal when an external
This terminal can be used as a common terminal when an external
power supply is used by changing SW1 to PLC side.
power supply is used by changing SW1 to PLC side.
DC power input terminal for operating the control circuit. Connect a
DC power input terminal for operating the control circuit. Connect a
control power backup device (option or 24Vdc power supply) between
control power backup device (option or 24Vdc power supply) between
+SU and CC.
+SU and CC.
It is used with STO for safety function.
It is used with STO for safety function.
+SU and STO terminals are short-circuited by metal bar and the inverter
+SU and STO terminals are short-circuited by metal bar and the inverter
is put into a standby state at default setting. When the circuit between
is put into a standby state at default setting. When the circuit between
them is opened, the motor is coasting stop.
them is opened, the motor is coasting stop.
When +SU and STO are short-circuited, the inverter is put into a
When +SU and STO are short-circuited, the inverter is put into a
standby state. (Default setting) And when the circuit between them is
standby state. (Default setting) And when the circuit between them is
opened, the motor is coasting stop. These terminals can be used for
opened, the motor is coasting stop. These terminals can be used for
inter lock.
inter lock.
This terminal is not a multifunction programmable input terminal.
This terminal is not a multifunction programmable input terminal.
It is a terminal with the safety function that complies with SIL II of the
It is a terminal with the safety function that complies with SIL II of the
safety standard IEC61508.
safety standard IEC61508.
Multifunction programmable open collector output. Default setting detect
Multifunction programmable open collector output. Default setting detect
and output speed reach signal.
and output speed reach signal.
Multifunction output terminals to which two different functions can be
Multifunction output terminals to which two different functions can be
assigned.
assigned.
The NO terminal is an equipotential terminal. It is isolated from the CC
The NO terminal is an equipotential terminal. It is isolated from the CC
terminal.
terminal.
By changing parameter f669 settings, these terminals can also be
By changing parameter f669 settings, these terminals can also be
used as multifunction programmable pulse train output terminals.
used as multifunction programmable pulse train output terminals.
Multifunction programmable relay contact output.
Multifunction programmable relay contact output.
Detects the operation of the inverter's protection function.
Detects the operation of the inverter's protection function.
Contact across FLA-FLC is closed and FLB-FLC is opened during
Contact across FLA-FLC is closed and FLB-FLC is opened during
protection function operation.
protection function operation.
Multifunction programmable relay contact output.
Multifunction programmable relay contact output.
Default settings detect and output low-speed signal output frequencies.
Default settings detect and output low-speed signal output frequencies.
Multifunction output terminals to which two different functions can be
Multifunction output terminals to which two different functions can be
assigned.
assigned.
Function
Function
46
11
11
E6582383
E6582383
E6582383
Electrical
Electrical
specifications
specifications
24Vdc-100mA
24Vdc-100mA
-
-
Voltage:
Voltage:
24Vdc±10%
24Vdc±10%
Current:
Current:
1A or more
1A or more
-
-
Independently of
Independently of
SW1
SW1
ON: DC17V or
ON: DC17V or
more
more
OFF: DC12V or
OFF: DC12V or
less
less
(OFF: Coast stop)
(OFF: Coast stop)
Open collector
Open collector
output
output
24Vdc-100mA
24Vdc-100mA
To output pulse
To output pulse
trains,
trains,
a current of 10mA
a current of 10mA
or more needs to
or more needs to
be passed.
be passed.
Pulse frequency
Pulse frequency
range:
range:
10~2kpps
10~2kpps
Max. switching
Max. switching
capacity
capacity
250Vac-2A,
250Vac-2A,
30Vdc-2A
30Vdc-2A
(cosφ=1)
(cosφ=1)
: at resistive load
: at resistive load
250Vac-1A
250Vac-1A
(cosφ=0.4)
(cosφ=0.4)
30Vdc-1A
30Vdc-1A
(L/R=7ms)
(L/R=7ms)
Min. permissible
Min. permissible
load
load
5Vdc-100mA
5Vdc-100mA
24Vdc-5mA
24Vdc-5mA