Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba TOSVERT VF-S15 Schnellstartanleitung Seite 46

Vorschau ausblenden Andere Handbücher für TOSVERT VF-S15:
Inhaltsverzeichnis

Werbung

Terminal
Terminal
Input /
Input /
symbol
symbol
output
output
F
F
Input
Input
R
R
Input
Input
RES
RES
Input
Input
S1
S1
Input
Input
S2
S2
Input
Input
S3
S3
Input
Input
Common
Common
CC
CC
to Input /
to Input /
Control circuit's equipotential terminal (3 terminals)
Control circuit's equipotential terminal (3 terminals)
output
output
PP
PP
Output
Output
Analog power supply output
Analog power supply output
Multifunction programmable analog input.
Multifunction programmable analog input.
Default setting: 0-10Vdc (1/1000 resolution) and 0-60Hz (0-50Hz)
Default setting: 0-10Vdc (1/1000 resolution) and 0-60Hz (0-50Hz)
V I A
V I A
frequency input.
frequency input.
Input
Input
Note 1)
Note 1)
By changing parameter f109, this terminal can also be used as a
By changing parameter f109, this terminal can also be used as a
multifunction programmable logic input terminal.
multifunction programmable logic input terminal.
Multifunction programmable analog input.
Multifunction programmable analog input.
Default setting: 0-10Vdc (1/1000 resolution) and 0-60Hz (0-50Hz)
Default setting: 0-10Vdc (1/1000 resolution) and 0-60Hz (0-50Hz)
frequency input.
frequency input.
V I B
V I B
The function can be changed to -10-+10V input (1/2000 resolution) by
The function can be changed to -10-+10V input (1/2000 resolution) by
Input
Input
parameter f107 =1 setting.
parameter f107 =1 setting.
Note 1)
Note 1)
By switching slide switch SW2 and changing parameter f109 setting,
By switching slide switch SW2 and changing parameter f109 setting,
this terminal can also be used as a multifunction programmable logic
this terminal can also be used as a multifunction programmable logic
input terminal.
input terminal.
Multifunction programmable analog input.
Multifunction programmable analog input.
V I C
V I C
Input
Input
4-20mA (0-20mA) input.
4-20mA (0-20mA) input.
Multifunction programmable analog output. Default setting: output
Multifunction programmable analog output. Default setting: output
frequency.
frequency.
FM
FM
Output
Output
The function can be changed to meter option (0-1mA), 0-10Vdc voltage
The function can be changed to meter option (0-1mA), 0-10Vdc voltage
or 0-20mAdc (4-20mA) current output by parameter f681 setting.
or 0-20mAdc (4-20mA) current output by parameter f681 setting.
Resolution Max. 1/1000.
Resolution Max. 1/1000.
Function
Function
Shorting across F-CC or P24-F causes forward rotation; open
Shorting across F-CC or P24-F causes forward rotation; open
causes deceleration stop.
causes deceleration stop.
(When Standby ST is always ON)
(When Standby ST is always ON)
3 different functions can be assigned.
3 different functions can be assigned.
Shorting across R-CC or P24-R causes reverse rotation; open
Shorting across R-CC or P24-R causes reverse rotation; open
causes deceleration stop.
causes deceleration stop.
(When Standby ST is always ON)
(When Standby ST is always ON)
3 different functions can be assigned.
3 different functions can be assigned.
This inverter protective function is reset if RES-CC or P24-RES is
This inverter protective function is reset if RES-CC or P24-RES is
connected. Shorting RES-CC or P24-RES has no effect when the
connected. Shorting RES-CC or P24-RES has no effect when the
inverter is in a normal condition.
inverter is in a normal condition.
2 different functions can be assigned.
2 different functions can be assigned.
Shorting across S1-CC or P24-S1 causes preset speed operation.
Shorting across S1-CC or P24-S1 causes preset speed operation.
2 different functions can be assigned.
2 different functions can be assigned.
Shorting across S2-CC or P24-S2 causes preset speed operation.
Shorting across S2-CC or P24-S2 causes preset speed operation.
By changing parameter f146 setting, this terminal can also be
By changing parameter f146 setting, this terminal can also be
used as a pulse train input terminal.
used as a pulse train input terminal.
Shorting across S3-CC or P24-S3 causes preset speed operation.
Shorting across S3-CC or P24-S3 causes preset speed operation.
By changing slide switch SW2 and parameter f147 setting, this
By changing slide switch SW2 and parameter f147 setting, this
terminal can also be used as a PTC input terminal.
terminal can also be used as a PTC input terminal.
45
10
10
E6582383
E6582383
E6582383
Electrical
Electrical
specifications
specifications
No voltage
No voltage
logic input
logic input
24Vdc-5mA or
24Vdc-5mA or
less
less
Sink/Source and
Sink/Source and
PLC selectable
PLC selectable
using slide switch
using slide switch
SW1
SW1
(Default setting is
(Default setting is
Sink side)
Sink side)
Pulse train input
Pulse train input
(S2 terminal)
(S2 terminal)
Pulse frequency
Pulse frequency
range:
range:
10pps~2kpps
10pps~2kpps
Duty: 50±10%
Duty: 50±10%
PTC input
PTC input
(S3 terminal)
(S3 terminal)
-
-
10Vdc
10Vdc
(permissible load
(permissible load
current: 10mAdc)
current: 10mAdc)
10Vdc
10Vdc
(internal
(internal
impedance: 30kΩ)
impedance: 30kΩ)
10Vdc
10Vdc
(internal
(internal
impedance: 30kΩ)
impedance: 30kΩ)
4-20mA
4-20mA
(internal
(internal
impedance: 250Ω)
impedance: 250Ω)
1mAdc full-scale
1mAdc full-scale
ammeter or
ammeter or
QS6T(option)
QS6T(option)
0-20mA (4-20mA)
0-20mA (4-20mA)
DC ammeter
DC ammeter
Permissible load
Permissible load
resistance:
resistance:
600Ω or less
600Ω or less
0-10V DC volt
0-10V DC volt
meter
meter
Permissible load
Permissible load
resistance:
resistance:
1kΩ or more
1kΩ or more

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis