SEQ PARAM SET
GRP MST/FOLLOWER
GRP MODE
GRP NUMBER 0002
GRP SWITCH
GRP LD
GRP ULD
GRP DELAY
RST MAINT TIME
OIL FILTER
0000H
SEPARATOR
0000H
AIR FILTER
0000H
OIL
0000H
GREASE M1
0000H
BELTS
0000H
MAX RUN TIME
OIL FILTER
0500H
SEPARATOR
4000H
AIR FILTER
2000H
OIL
0500H
GREASE M1
4000H
BELTS
4000H
USER PASS
ENTER PASSWORD
LANG.
LANGUAGE
If there is no activity for 60 seconds in the current menu, the control will automatically return to the main menu.
+7 (800) 777-83-75(звонок бесплатный)
www.v-p-k.ru
— group parameters
Options: master / follower (slave).
V-V/V-F
Options: individual operation / group.
Number of the compressor within the group.
0099H
05.2 BAR Group load pressure.
08.0 BAR Group idle run pressure.
0020s
Group delay, wait time until next compressor switches.
— resetting of the maintenance hours counter
Oil filter maintenance. Set to 0 after maintenance.
Separator maintenance. Set to 0 after maintenance.
Air filter maintenance. Set to 0 after maintenance.
Oil. Set to 0 after changing.
Lubricate motor bearings. Set to 0 after maintenance.
Change belts. Set to 0 after maintenance.
— set maintenance intervals.
Oil filter maintenance. Set maintenance interval.
Separator maintenance. Set maintenance interval.
Air filter maintenance. Set maintenance interval.
Oil. Set change interval.
Lubricate motor bearings. Set maintenance interval.
Change belts. Set to 0 after maintenance.
— user password
****
No access to parameter
— language
........ EN/DE