The surface of the
appliance is very hot
Traces of dirt
appear on the wall
around the
appliance
The appliance does
not follow the
internal
programming
commands
The screen shows
The screen shows
The screen shows
The screen shows
The appliance does
not follow the Pilot
wire commands
dimensions of the room and your structure. Also ensure that the product
is heating an enclosed area.
It is normal that the appliance is hot when operating and the maximum
surface temperature is limited in accordance with the NF Electricity
standard. If, however, you feel that your appliance is always very hot, check
the ambient temperature of the room. If this is higher than the set
temperature, refer to the section "The appliance is heating constantly".
Otherwise, the appliance is heating to the correct power for its output and
the dimensions of the room
In a polluted atmosphere, dirt may appear around the appliance's air outlets
or on the wall. This phenomenon is linked to the poor ambient air quality
(cigarette smoke, candles, incense, fireplace, etc.). In this case, you are advised
to check that the room is suitably ventilated (ventilation, air intake, etc.).
Check that the date and time are set.
Check that the appliance is in Programming mode
This symbol is displayed when an open window is detected.
This symbol is displayed when the appliance is in Pilot wire mode, when it
receives a priority command or when you want to change the temperature.
This symbol is displayed when the appliance is overheating. Contact the
After-Sales service.
This symbol is displayed when the appliance sensor is defective. Contact the
After-Sales service.
Make sure that the programming unit is being used correctly (see unit user
manual).
Check that the appliance is not in Programming mode. Check that the
programming commands are correctly transmitted:
Comfort
Signal to be
transmitted
Measurement
0 Volts
between the
Pilot Wire and
neutral
When controlled by pilot wire or carrier load, frost protection or load
shedding commands have priority.
The switch time from Comfort mode to Eco mode is around 12 seconds.
The switch time from Comfort -1/-2 to Comfort mode is around 5 minutes.
Eco
Frost
Protection
230
-115
Volt
negative
Volts
34
Heating
Comfort
off Load
-1°C
shedding
+115
230 Volts
positive
for 3 s
Volts
Comfort
-2°C
230 Volts
for 7 s