Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Ferroli EGEA 90 LT Handbuch Für Betrieb Und Installation

Vorschau ausblenden Andere Handbücher für EGEA 90 LT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 254
2.13

TROUBLESHOOTING

If the equipment is not working properly, without any alarm signaling, before contacting the manufacturer's technical assistance
service, it is advisable to carry out the following.
Malfunction
The equipment does not switch on.
Water cannot be heated via the heat pump
in ECO or AUTOMATIC mode
The heat pump stays on continuously and
never turns off
Water cannot be heated via the integrated
heating element in AUTOMATIC mode
The product cannot be controlled via APP
124
EN
Recommended action
Check that the plug is properly inserted in the socket.
Check that the ignition procedure has been carried out from the control
panel (ref. par. 2.5 on page 116).
Disconnect the plug from the socket (without pulling the power cord)
and wait a few minutes; insert the plug back into the socket.
USER
If the problem persists: contact a qualified technician or the technical assis-
tance service.
Check the status of the power cable inside the product.
Check that the fuse on the power board is intact. Otherwise, replace it
with a new delayed 5 A 250V, IEC 60127-2/II (T5AL250V) certified (refer
EXPERT TECHNICIAN
to par. 7.1 on page 146).
/ MANUFACTURER'S
TECHNICAL
ASSISTANCE
Turn off the device (ref. par. 2.5 on page 116) and turn it back on after
a few hours.
If the problem persists: contact a qualified technician or the technical assis-
tance service.
USER
Disconnect the device from the power grid.
Drain part of the water contained in the tank (about 50%) and refill it.
EXPERT TECHNICIAN
Turn the appliance on again in ECO mode.
/ MANUFACTURER'S
TECHNICAL
ASSISTANCE
Check that, by not opening any valve for a few hours, the equipment
reaches the set point temperature.
If the problem persists: contact a qualified technician or the technical assis-
tance service.
USER
• Switch off the device and check the safety thermostat of the heating
element inside the device and reset it if necessary. Then turn on the
equipment in AUTOMATIC mode.
• Disconnect the device from the power supply then drain part of the
water contained in the tank (about 50%) then recharge it and turn the
device back on in AUTOMATIC mode.
EXPERT TECHNICIAN
• Enter the installer menu and increase the value of parameter P32 for
/ MANUFACTURER'S
TECHNICAL
example to 7°C.
ASSISTANCE
• Check that the electrical resistor safety thermostat has not intervened
(ref. par. 7.2 on page 146).
• Check that there is Wi-Fi network coverage, e.g. via smartphone
where the product is installed, then carry out the configuration proce-
dure again with the router.
• Then ensure that the Wi-Fi symbol on the display is steady on.
USER