3.12
Stator coupling and mounting
3.13
Cable laying
8017140/1EF5/2021-12-10 | SICK
Subject to change without notice
4
1
2
Figure 13: Mounting with square flange
Item description
Stator coupling
2-sided, slot, bolt circle 63–83 mm
without stator coupling
2-sided, bolt circle 63 mm
pin block mounting
1-sided, slot, bolt circle radius 33–48.5 mm
1-sided, slots, bolt circle radius 32.25–142.65
mm
1-sided, slot, bolt circle radius 32.1–37.6 mm
pin block mounting
For models without stator coupling (Variant A), sufficient decoupling between encoder
and application is mandatory.
Insufficient decoupling can lead to mechanical damage of the encoder.
•
Align cable outlet / connector downwards to avoid moisture ingress into connector.
•
Loop the cable back upwards to create a drip loop to carry liquids away from the
encoder connection.
•
Mind the permissible bending radius of the cable.
Figure 14: Cable laying
OPERATING INSTRUCTIONS
3
Var.
0
2x M3
A
4x M2,5
B
4x M3
C
see Mounting with pin
block mounting, page 21
D
1x M5
E
1x M4
G
1x M4
K
see Mounting with flange
version K, page 20
O P E R A T I N G I N S T R U C T I O N S | DBS60 Core
Screws
25
DBS60 Inox