Herunterladen Inhalt Inhalt Diese Seite drucken

Fault Rectification - User; Fault Rectification - Qualified Installer - STIEBEL ELTRON SHZ 30 LCD Montageanleitung

Vorschau ausblenden Andere Handbücher für SHZ 30 LCD:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
6. Fault rectification
Fault
No hot water.
No flow
rate.
Service symbol
appears.
Defect
symbol
flashing.
Table 2
7. Fault rectification
Fault / defect code / Info
No display in the control
Service symbol.
Code
Continuous display -
setpoint temperature.
Code
Continuous display -
outlet
temperature.
Code
No anode
protection.
Code
Last preset setpoint values
active. Possibly continuous
display of
Defect symbol
>> flashing.
Code
Continuous display -
setpoint
temperature.
Code
No display of heating
element
symbol.
Code
Running dry
Code
Table 3
18
by the user
Info
No
voltage.
Dirt or limescale in the perlators in the
fittings or shower
Water heating continues
(see Table
No water heating
(see Table
by the qualified installer
Possible cause / defect
panel.
No
voltage.
No connection to the control
Control unit
Water heating continues.Maintenance
requirement.
Temperature sensor
Temperature sensor
Parasitic current anode
Communication fault with electronic
„regulator" and „control unit"
.
No water
Temperature sensor
Safety thermal cut-out (STB)
Heating element
protection.
No water in the
No anode
Relay
defective.
heads.
3).
3).
unit.
defective.
fault.
fault.
fault.
modules.
heating.
defective.
actuated.
defective.
reservoir.
current.
Rectification
heck fuses in the house
installation.
Clean and/or descale the outlet
Service/maintenance is
required.
Corrective maintenance urgently required;
inform qualified
installer.
Rectification
Restore voltage
supply.
Check that connector „X2" is correctly
H
fitted
.
Check control unit (20) and if necessary
replace.
Service code enquiry.
Service / maintenance
required.
Check that connector „X10" is correctly
L
fitted
.
Inspect temperature sensor.
Check that connector „X10" is correctly
L
fitted
.
Inspect temperature sensor.
Check that connector „X7" is correctly
L
fitted
.
Check parasitic current anode and
wiring.
Check that connector „X2" is correctly
H
fitted on both modules
.
Check connection cable and
modules.
Defect code enquiry.
Corrective maintenance urgently required!
Check that connector „X10" is correctly
L
fitted
.
Inspect temperature
Ursache beheben und entriegeln; STB kon-
trollieren ggf. austauschen.
Rectify cause and unlock; inspect STB and if
necessary
replace.
Fill the reservoir with
water.
Check that connector „X7" is correctly
L
fitted
.
Inspect parasitic current anode
and
wiring.
Replace regulator electronic module
fittings.
sensor.
( 22 ).