INSTALLATION
Specification

15.3 Heat-up diagrams

The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
Graph assumes 15 °C cold water inlet temperature:
6
5
4
3
2
1
0
35
45
X Temperature setting [°C]
Y Heat-up time [h]
1 200 l
2 150 l
3 120 l
4 100 l
5 80 l
6 50 l
7 30 l

15.5 Details on energy consumption

Product datasheet: Conventional water heaters to regulation (EU) no. 812/2013 and 814/2013 / (S.I. 2019 No. 539 / Schedule 2)
Manufacturer
Load profile
Energy efficiency class
Energy conversion ef-
%
ficiency
Annual power consump-
tion
Daily power consump-
kWh
tion
22
| PSH Trend
1
2
3
4
5
6
7
55
65
75
PSH-H 30
PSH-H 50
Trend
Trend
204770
204771
STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
S
M
C
C
33
36
568
1428
2.729
6.697

15.4 Fault conditions

In the event of a fault, temperatures of up to 95 °C at 0.6 MPa
can occur.
PSH-H 80
PSH-H 100
Trend
Trend
204772
204773
M
M
C
C
37
36
1404
1427
6.558
6.693
PSH-H 120
PSH-H 150
Trend
Trend
204774
204775
L
L
C
C
37
38
2758
2715
12,828
12.575
www.stiebel-eltron.com
PSH-H 200
Trend
204776
L
C
37.2
2750
12.779

Werbung