Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions; Unit Structure; Fittings; Technical Data - STIEBEL ELTRON SHZ 30 LCD Montageanleitung

Vorschau ausblenden Andere Handbücher für SHZ 30 LCD:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6

3. Installation instructions

3.1

Unit structure

D H L M N
15
Control panel
16
Hot water outlet nozzle G ½
17
Cold water inlet nozzle G ½
18
Heating element
19
Parasitic current anode
20
Electronic module (control unit)
21
Reset button of safety thermal cut-out
22
Electronic module (regulation)
23
Safety thermal cut-out
24
Sealing ring
25
Draining valve with hose connection G ¾
26
Aperture for customer provided remote
control of rapid heating in combination
with PG 11
27
Cable aperture PG 21 for electrical
connection
28
Inflow
29
Outflow pipe
30
Suspension bracket, top*
31
Suspension bracket, bottom*
(SHZ 120 LCD, SHZ 150 LCD only)
32
Connection cable for „electronic
modules"
33
Sliding switch for operating modes
34
Sliding switch for output variants
35
Unit connection terminal
36
Temperature sensor
37
Parasitic current anode
38
Customer provided remote control for
rapid heating
39
Customer provided power supply
company contact
* for customer provided screws 12 mm dia.

3.2 Fittings

! Unvented (pressurized) mode of
operation: Safety groups kV 30 or kV 40
F
.
! Vented (pressureless) mode of operation:
G
Fittings without pressure

Technical data

(the data on the unit rating plate are applicable)
Type
SHZ 30
LCD
Capacity
l 30
Mixed water quantity
l 59
40 °C (15 °C / 65 °C)
Weight empty
kg 23.5
Connectable to power
sources
Permissible operating
pressure
Protection class
EN 60529
Test marking

Water connection

Flow rate
Dimensions
a
mm
420
D
b
mm
410
h
mm
750
i
mm
k
mm
700
l
mm
70
Table 1
16
for the qualified installer
3.3 Regulations and
provisions
! The installation (water and electrical
installation) and first start-up, as well as the
maintenance of this unit may only be
carried out by an approved specialist
installer in accordance with these
Instructions.
! Perfect function and operational safety are
only guaranteed with original accessories
and spare parts intended for the unit.
!
IEE Regulations (electrical).
! Provisions of the local energy supply utility
company.
!
WRC Regulations (water).
! Provisions of the water supply utility
company responsible.
The following are also to be respected:
! The unit rating plate
! Technical data

! Water installation

Pipe material:
– Cold water pipe
Copper pipe
Steel pipe
Plastic pipe systems:
Installation also in conjunction with
DVGW-tested plastic pipe system for
cold-water and hot-water pipe systems.

! Electrical installation

– Electrical connection only with fixed-laid
leads in association with removable
cable bushings.
– The unit must be capable of all-pole
disconnection from the mains, for
example by fuses, with an isolating
distance of at least 3 mm.
.
SHZ 50
SHZ 80
SHZ 100
LCD
LCD
LCD
50
80
100
97
159
198
30
44
45
1 - 4 kW
1/N/PE ~ 230 V
1 - 4 kW
2/N/PE ~ 400 V
1 - 6 kW
3/N/PE ~ 400 V
0.6 MPa (6 bar)
IP 25 D
See unit rating plate
G
½ (external thread)
max. 18 l/min
510
510
510
510
720
1030
1030
600
900
140
150
– Hot water pipe
Copper pipe
Steel or copper pipe
SHZ 120
SHZ 150
LCD
LCD
120
150
235
292
50
62.5
510
510
510
510
510
510
1190
1425
300
300
900
900
1100
150
310
345

3.5 Installation location

! Install in a vertical position; see
! In an area not subject to the risk of
freezing.
! Install close to the water tap.

3.6 Unit installation

! Fit the suspension bracket.
Select the securing material to suit the
strength of the wall. With SHZ 120 LCD
and SHZ 150 LCD, two suspension
brackets are required.
Any unevenness in the wall is to be
compensated for by the spacer elements
C
provided (a. approx. 5 mm thick).
!
Suspend the unit.
!
Push the cover caps onto the suspension
bracket (b).
3.7 Water connection
! Unvented (pressurized) for the
supply of several draw-off points.
– Install the type-tested safety groups
KV 30, Order No. 00 08 26, up to
0.48 MPa water pipe pressure
KV 40, Order No. 00 08 28, up to 1 MPa
water pipe pressure
a Safety valve
b Backflow preventer
c Test valve
d Throughflow isolating valve (choke)
e Pressure reducer (with KV 40)
f Test nozzle for pressure gauge
g Thermostat fitting TA 260
Order No. 00 34 66 (order
separately), also possible in conjunction
with KV 40.
– Establish dimensions for the outflow pipe
for a fully-opened safety valve. The drain
aperture of the safety valve must remain
open to the atmosphere.
– The drain for the safety group is to be
installed with a constant downwards
inclination.
– The information provided in the
Installation Instructions for the safety
group are to be respected.
– Set a maximum flow rate of 18 l/min at
the choke of the safety group.
! Vented (pressureless) for the supply
of one single draw-off point
The units are suitable for vented
(pressureless) operation mode.
Do not block off the drain and
fittings pivot arm.
– With this installation the Stiebel Eltron
fittings for vented wall-mounted water
G
heaters
are to be used.
– Before connecting the fitting the water
pipe must be thoroughly flushed through.
– Each time heating takes place, expansion
water will drip out of the drain.
– For use, installation, first start-up, and
maintenance, the same instructions apply
as for the operation of unvented
(pressurized) water heaters.
D
.
E
F

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis