Planning the installation
8.1
Installation Guidance
► Commission a qualified electrician to install the product.
► Observe the Assembly and installation instructions.
Installation Guidance
TN system
IT system
Earthing
TT system
1-phase
Input
Three-phase
C characteristic, selection according to the manufacturer's
Circuit breakers
specification and current strength settings for the EV charging
box
RCD
30 mA AC, type A
► Ensure that the intended earthing connection conforms to the local valid
specifications.
► Observe the required triggering characteristic for the residual current
protective device, depending on local specifications and on the vehicle
manufacturer, e.g. type B.
PE conductor
Earthing electrode (to be installed
separately)
230 V, 50 Hz (TN, IT/TT)
400 V, 50 Hz (TN)
230 V, 50 Hz (TN, IT/TT)