5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
The scarifi er is delivered unassembled. The grass
basket and the complete push bar must be as-
sembled and mounted before using the scarifi er.
Follow the operating instructions step-by-step
and use the pictures provided as a visual guide to
easily assemble the machine.
Fitting the push bar brackets (see Figs. 5
and 6)
Remove the quick-release lever (Fig. 5/
Item 13) and the washer (Fig. 5/Item 14)
Connect the push bar bracket (Fig. 5/Item 7)
to the fastening screw. Make sure that the
curve in the tube (Fig. 6/Item A) is on the out-
side.
Now put the washer back on and tighten with
the quick-release lever.
The same tilt angle must be set for both push bar
brackets!
Fitting the lower push bar (see Fig. 7)
Slide the lower push bar (Fig. 7/Item 6) onto
the push bar brackets. Do not forget to slip
the stress-relief clip (Fig. 7/Item 4) onto the
tube first.
Now join the tubes together using the screws
(Fig. 7/Item 15), washers (Fig. 7/Item 14) and
quick-release levers (Fig. 7/Item 13) supplied.
Fitting the upper push bar (see Fig. 8 to
Fig. 10)
The upper push bar (Fig. 8/Item 3) has two
holes one beneath the other for further height
adjustment of the push bar.
Position the upper push bar (Fig. 8 / Item 5)
such that its holes line up with the holes of the
lower bar.
Now join the tubes together using the screws
(Fig. 8/Item 15), washers (Fig. 8/Item 14) and
quick-release levers (Fig. 8/Item 13) supplied.
Use the cable clips (Fig. 9/Item 12) to attach
the power cable to the tubes of the push bars
so that it is possible to open and shut the
ejector flap (Fig. 10/Item 12).
Please ensure that the ejector fl ap can be opened
and closed easily!
Anl_GE_SA_1435_1_SPK13.indb 20
Anl_GE_SA_1435_1_SPK13.indb 20
GB
Assembling the grass basket
(see Figs. 11 and -14)
Pull the grass basket over the metal frame
(Fig. 12).
Pull the rubber clips over the metal frame
(Fig. 13).
To hang the grass basket on the scarifier you
must lift the ejector flap (Fig. 14/Item 10) with
one hand and with the other hand take hold of
the grass bag by the handle and hook it onto
the scarifier from above (Fig. 14).
Danger!
Before you ever hook the grass basket to the sca-
rifi er you must ensure that the motor is switched
off and the cutting unit is not rotating.
Adjusting the handlebar height (see Fig. 15)
Undo the quick-release levers (Fig. 15/Item 13)
on both sides of the scarifi er.
The height of the handlebar can be set to position
1 or 2 (Fig. 15) during operation. You must then
tighten the quick-release fasteners again.
The same tilt angle must be set on both sides.
Adjusting the scarifi er depth (see Fig. 16)
The scarifi er depth is set with the adjustment me-
chanism. Pull the lever in the direction indicated
by the arrow (see Fig. 16) and adjust to the re-
quired position (+3/ -3/ -6/ -9). Make sure that the
lever latches in place correctly!
+3 = drive/transport position +3 mm
-3 = scarifi er depth -3 mm
-6 = scarifi er depth -6 mm
-9 = scarifi er depth -9 mm

Electrical connection

The equipment can be connected to any normal
socket with 230V AC. It is only acceptable to con-
nect it to a shockproof socket with a 16A circuit
breaker. Furthermore, a residual-current-operated
protective device with max. 30 mA should be con-
nected upstream.
Power cable
Please only use power cables that are not dama-
ged. The total length of the power cable should
not exceed 50 meters; going beyond this distance
will reduce the power output of the electric motor.
The power cable must have a cross-section of 3 x
1.5 mm2. The insulating sheath of scarifi er power
cables is frequently damaged.
Some of the causes for this are:
Cracking from running over the cable
- 20 -
28.06.2022 08:53:03