Herunterladen Inhalt Inhalt Diese Seite drucken

Residual Risks; Technical Data - Scheppach HC30o Original Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HC30o:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
7.
Do not smoke during the spraying process and/or
in the work area. Risk of explosion! Paint vapours
are easily combustible.
8.
Never set up or operate the equipment in the vicini-
ty of a fire place, open lights or sparking machines.
9.
Do not store or eat food and drink in the work area.
Paint vapours are harmful to your health.
10. The work area must exceed 30 m³ and sufficient
ventilation must be ensured during spraying and
drying.
11. Do not spray against the wind. Always adhere to
the regulations of the local police authority when
spraying combustible or hazardous materials.
12. Do not process media such as white spirit, butyl
alcohol and methylene chloride with the PVC pres-
sure hose.
13. These media will destroy the pressure hose.
14. The work area must be separated from the com-
pressor so that it cannot come into direct contact
with the working medium.
Operation of pressure vessels
• Anyone who operates a pressure vessel must keep
this in good working order, operate and monitor it
correctly, perform the necessary maintenance and
servicing works immediately and implement safe-
ty measures as required according to the circum-
stances.
• The regulatory authority can instruct necessary
monitoring measures in individual cases.
• A pressure vessel must not be operated if it exhib-
its a defect that poses a danger to personnel or
third parties.
• Check the pressure vessel for rust and damage
each time before use. The compressor shall not be
operated if the pressure vessel is damaged or rusty.
If you discover damage, please contact the custom-
er service workshop.
m WARNING! This power tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain con-
ditions. In order to prevent the risk of serious or deadly
injuries, we recommend that persons with medical im-
plants consult with their physician and the manufactur-
er of the medical implant prior to operating the power
tool.
Keep these safety instructions in a safe place.
24 | GB

6. Residual risks

The machine has been built according to the state-of-
the-art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the "Safety infor-
mation" and the "Proper use" together with the oper-
ating manual as a whole are observed.
• Avoid accidental starting of the machine: the oper-
ating button may not be pressed when inserting the
plug in an outlet. Use the tool that is recommended
in this operating manual. This is how to ensure that
your machine provides optimum performance.
• Keep your hands away from the work area, when the
machine is in operation.
7.

Technical data

Mains connection
Motor power
Operating mode
Compressor speed
Pressure vessel capacity
Operating pressure
Theo. intake capacity
Theo. Power output
Protection category
Device weight
Technical changes reserved!
Noise and vibration
m Warning: Noise can have serious effects on your
health. If the machine noise exceeds 85 dB (A), please
wear suitable hearing protection.
Noise data
Sound power level L
Sound pressure level L
Uncertainty K
www.scheppach.com
97 dB(A)
WA
83,4 dB(A)
pA
2,16 / 3 dB(A)
wa/pA
230 V~ 50 Hz
1100 W
S1
2850 min
-1
ca. 24 l
ca. 8 bar
ca. 200 l/min
ca. 63 l/min
IP 30
18,3 kg

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

5906146901

Inhaltsverzeichnis